Section 6. Application Data

Introduction

The EntelliGuard G family of circuit breakers and related
switching devices is a truly global line of protection and
switching devices. It was designed from the ground up to
provide reliable protection and operation in a wide range of
power distribution systems. Combined with the EntelliGuard
TU family of trip devices, EntelliGuard G circuit breakers
provide superior protection and reliability with a maximum
of flexibility and a minimum of compromise for your power
protection and switching needs.
This section provides an overview of the circuit breaker's
capability under UL 489 and UL 1066 standards.

Key Features

There are three product families:

UL1066 Low Voltage Power Circuit Breakers

800-5000A frames in three physical sizes.
400-5000A sensors with rating plugs as low as 150A and
trip settings as low as 75A.
Short circuit ratings as high as 150kA at 480V (tested at
508V).
Withstand capability and selectivity as high as 100kA
Continuously adjustable selective instantaneous as high
as 30X the circuit breaker's rating.
UL489 Stored Energy Insulated Case Circuit Breakers
800-6000A frames in three physical sizes.
400-6000A sensors with rating plugs as low as 150A and
trip settings as low as 75A.
Short circuit ratings as high as 150kA at 480V.
Withstand capability and selectivity as high as 100kA.
Continuously adjustable selective instantaneous to 15X
on all but the largest circuit breakers.
Draw-out and stationary mounted, 100% rated in most
sizes.
IEC Rated Circuit Breakers for IEC Equipment and
Applications
800-6400A frames in three physical sizes.
400-6400A sensors adjustable to 20% of sensor size.
Short circuit ratings as high as 150kA at 440V, 100kA at
690V, 80kA at 1000V.
Rated breaking capacity 100%, Ics = Icu for all frames.
Withstand capability and selectivity as high as 100kA for
1sec.
Continuously adjustable selective instantaneous as high
as 30X the circuit breaker's rating.
©2012 General Electric All Rights Reserved
EntelliGuard

All Types

Stationary mounting capability with rear or front
connections.
Draw-out mounting with cassette and automatic shutter
mechanism.
Complete closed door operation capability – UL489,
ANSI or IEC.
Two-step stored energy mechanism for manual or
electrically operated circuit breakers, suitable for fast
throw-over or generator paralleling applications
Remote racking device allowing maintenance personnel
to rack circuit breakers in and out while standing outside
the arc flash boundary.
3 and 4 pole configurations with the neutral on either
side.
Suitable for UL1008 transfer switch applications
Alternate, settable and remote controllable
instantaneous pickup with positive feedback.
Industry's only fully controllable ZSI restrained and
unrestrained settings.
Industry's only fully selective instantaneous trip with
selectivity enhancing ZSI capability.
Field installable accessories with labels that may be
seen through the circuit breaker's escutcheon.
Easily accessible terminal contacts at the top or side of
circuit breaker for use by installer – permanently labeled,
color coded and interlocked with harnesses for fast,
efficient, mistake-proof wiring.
Advanced protection algorithms that allow maximum
selectivity and protection at the same time with
minimized need to sacrifice protection to get system
reliability or visa versa.
Trip curves and algorithms to optimally accommodate
downstream fuses, older slower power circuit
breakers, ultra fast current limiting devices or other
EntelliGuard circuit breakers without sacrificing any
more protection than absolutely necessary to achieve
significant selectivity.

Ratings and Sizes

The EntelliGuard G family of overcurrent devices is available
in 3 or 4 pole versions, in 3 physical sizes referred to as
"envelopes" 1, 2 and 3. Four pole versions may have the
neutral on the right- or left-most pole. The envelope and the
number of poles are the main determinants for physical size
and the space the device will require when installed in
equipment or enclosures.
The circuit breakers and switches are further divided into
"frame" sizes. The frame sizes follow the guidelines defined
®
G Circuit Breaker Application Guide
Section 5. Catalog Numbering Guide