Item name
Per page status corrected error over threshold:
100000: offline-failed
10000000: offline
Per page status uncorrected error:
CPU errors
CPUx/corey
corrected errors:
x total
uncorrected errors:
CPU1/uncore
Per CPU status corrected error over threshold:
/sys/devices/system/cpu5
/sys/devices/system/cpu15 offline
/sys/devices/system/cpu16 online
Table 5-1 mcemonitor command
offline-failed
Description
Shows result of Memory Page Offline.
Indicates that offlining failed for 0x10000 page of
memory address.
Indicates 0x10000 page of memory address was
offlined.
Show Memory Page that uncorrected error occurred.
Shows CPU fault information.
Shows fault information of CPU core.
CPU x: Indicates physical CPU socket number (x).
corey: Indicates CPU core number (y).
Shows number of occurrence of correctable errors.
Indicates that errors occurred x times.
Shows number of occurrence of uncorrectable errors.
Fault information of CPU Uncore.
Shows result of CPU Offline.
Indicates that offlining logical processor 5 failed.
Indicates that offlining logical processor 5 succeeded.
Indicates that offlined logical processor 16 is returned
to online by user.
Note: This CPU was made offline due to failure. Do not
make it online.