Configuration; Capmonitor Configuration File; Mcemonitor Configuration File - NEC Express5800/A1040b User Manual

Machine check monitoring service
Hide thumbs Also See for Express5800/A1040b:
Table of Contents

Advertisement

3.3

Configuration

Machine Check Monitoring Service provides the following two configuration files. You can change
behavior of Machine Check Monitoring Service by modifying these configuration files. This section
describes available parameters and how to specify them.
 /opt/nec/capmonitor/conf/capmonitor.conf
 /opt/nec/mcemonitor/conf/mcemonitor.conf
3.3.1

capmonitor configuration file

capmonitor configuration file /opt/nec/capmonitor/conf/capmonitor.conf is used for configuration related
to CPU Core Online.
Note
3.3.2

mcemonitor configuration file

mcemonitor configuration file /opt/nec/mcemonitor/conf/mcemonitor.conf is used for configuration
related to CPU Core Offline and Memory Page Offline. Modify this file according to description below.
・mcemonitor.conf
# vi /opt/nec/mcemonitor/conf/mcemonitor.conf
#
# Config file for mcemonitor
#
# specify the internal action in mcemonitor to a cpu error
# off
no action
# account only account errors
# soft
try to offline CPU
core-ce-action = soft
# specify the internal action in mcemonitor to a page error
# off
no action
# soft
try to soft-offline page without killing any processes
memory-ce-action = soft
For details of capmonitor configuration file, refer to "Capacity Optimization
(COPT) User's Guide".
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/a2010bExpress5800/a2020bExpress5800/a2040b

Table of Contents