12.2.4.7 Calibrating sensors S1, S2, and S3 on ISO 30 electro-spindles

When you have replaced the sensor as instructed in section 12.2.4.6 , proceed as follows to
calibrate it.
1. Check whether the signal output from the sensor corresponds to that specified in section 11.6.1
in the table for the sensor you are calibrating. (See Figure 13.1 for sensor S3.)
2. If it does not, turn the sensor seat (4) until you obtain the output specified in the table for the
sensor you are calibrating. Hold the sensor in this position and tighten the fixing screw (6).

12.2.4.8 Calibrating sensors S1, S2, S3 and S4 on HSK F63 electro-spindles

A kit of gauges and shims is available to assist in calibrating HSK F63 sensors.
Their use is described in sections 12.2.4.9 and 12.2.4.10 .
i
The kit makes calibration not only quicker but more precise too. HSD strongly
recommends the use of this kit, given the importance that correct sensor calibration
has for machining safety.

12.2.4.8.1 Procedure for S1

When you have replaced the sensor as instructed in section 12.2.4.6 , proceed as follows to
calibrate it.
1. Check whether the signal output from sensor S1 corresponds to that specified in the table
below.
2. Turn the spindle shaft by hand and check whether the conditions in the table are fulfilled
throughout the 360° of a complete revolution.
3. If they are not, turn the sensor seat (4) until you obtain the output specified in the table. Hold
the sensor in this position and tighten the fixing screw (6).

12.2.4.8.2 Procedure for S2

When you have replaced the sensor as instructed in section 12.2.4.6 , proceed as follows to
calibrate it.
5801H0017 Rev. 02 _________________________________________________________ 78/98
CONDITION
Tool holder locked
No tool holder
Tool holder ejected
(collet open)
Figure 12.19
_____________________________________
S1
OUTPUT
+24 V
0 V
0 V
A
X
A
Ejector
B Reference measurement
X