Pioneer DDJ-RB Service Manual page 28

Dj controller
Table of Contents

Advertisement

1
1-4: Voltage value display mode
A
This mode is to monitor and indicate values of voltages (A/D conversion values) of various controls (faders and knobs).
[Controls to be tested]
The target controls of the test is faders and controls indicated in green in the figure below.
To change the target of the test, turn the rotary selector (BROWSE) clockwise or counterclockwise.
B
C
[Test procedures]
1. Select a test target by turning the rotary selector clockwise or counterclockwise.
At the beginning of this test mode, the control numbered 1 is selected.
As the rotary selector is turned by 1 click, the LED of the selected control will light in the order indicated below.
Clockwise rotation:
Counterclockwise rotation:
2. Which control is currently selected is indicated with lighting of the LED of the button corresponding to the selected control,
D
as shown in the figure above.
The LED with a number colored white corresponds to the control having the same number.
3. After the control to be tested is selected, press the rotary selector to start monitoring the A/D conversion values.
The reference value is the A/D conversion value monitored immediately after the monitoring started.
* The A/D conversion values being monitored are raw data.
4. The A/D conversion values being monitored are indicated with the CH level indicator.
The value range that can be displayed is from 0 to 1023.
E
[How to check the CH level indicator]
F
* When all LEDs of the CH level indicator is turned off, it means zero (0).
28
1
2
Rotary selector (BROWSE)
DDJ-RB
2
3
3
4
4

Hide quick links:

Advertisement

Table of Contents
loading