8-2
Dot Recognition Feedback
The feedback range of dot feedback is checked and corrected, and the present feedback value is
checked and reset. Besides, the feedback gain is checked and corrected.
• Feedback timer
Reset
The feedback value is reset for each nozzle.
All reset
The feedback value of all nozzles is reset all together.
• Feedback range
The threshold value of feedback range is increased and decreased.
Default
The feedback range is placed to the default setting value. Usually, set the default value.
• Feedback gain
The feedback is carried out at once for the larger value of feedback gain, and the change of
dispensing time gets large.
The value of feedback gain increases and decreases.
Default
The feedback gain is set to the default value (= 1.0).