Rain Bird RC-4Bi Instruction Manual

Rain Bird RC-4Bi Instruction Manual

Advertisement

RC-4Bi
RC-7Bi
RC-1260Bi
Instruction
Manual
Figure 1
A
B
(The RC-4Bi has a 20-minute pause position between station #4 and "REST.")

DESCRIPTION OF CONTROLS

A. HOUR DIAL with 23 CYCLE START PINS: The HOUR dial contains 23 pins for
scheduling automatic "Starts" on any hour (except midnight—which is day changeover
time). Embossed characters provide quick identification for each hour, AM or PM,
noon and midnight. Captive type pins are designed for simple push-pull operation.
B. DAY DIAL with 14 SCHEDULING PINS: The calendar DAY dial contains 14 cap-
tive pins for scheduling irrigation everyday or any day within a two week range. Each
pin represents a 24 hour period beginning at midnight. Embossed characters are on
the dial, adjacent to each day of the week.
C. STATION SELECTOR/INDICATOR DIAL: The STATION selector/indicator dial
contains the timing controls (D) for each of the stations. The dial automatically rotates
during a watering cycle with the current station appearing at the top, under the station
pointer. REST indicates the system is off and no watering is taking place. The dial is
also used for manual selection of any station for semi-automatic operation.
H
G
I
E
RC-7BI MODEL SHOWN
Refer to Figure 1
1
F
C
D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RC-4Bi and is the answer not in the manual?

Questions and answers

Summary of Contents for Rain Bird RC-4Bi

  • Page 1 Manual Figure 1 RC-7BI MODEL SHOWN (The RC-4Bi has a 20-minute pause position between station #4 and "REST.") DESCRIPTION OF CONTROLS Refer to Figure 1 A. HOUR DIAL with 23 CYCLE START PINS: The HOUR dial contains 23 pins for scheduling automatic "Starts"...
  • Page 2 D. STATION TIME CONTROL KNOBS: Individual TIME controls for each station. Timing is adjustable up to 60 minutes to suit all landscape growth requirements. A small white arrow moves with each knob along the timing scale on the Station dial (C) for visual indication of the time setting.
  • Page 3 6: Blue tion output lead using wire nuts. 7: Violet NOTE: If the Master Valve/Pump Start circuit is used, 8: Gray connect only one Rain Bird, 2 watt, solenoid valve per 9: White 10: White/Blk station. 11: White/Bm 2. Connect the second lead from all valves to the white 12: White/Red common output lead.
  • Page 4 Instructions for Attaching Plug-In Transformer. Prior to plugging the transformer into a 120 VAC wall receptacle, insert the wire through the " hole in the lower left corner of the controller, tie an overhand knot in the wire about 5" from the end (inside the case).
  • Page 5 Example: If the correct time is 1:35 PM, position the dial such that the TIME pointer will point midway between the 1 and 2 numerals on the PM side of the dial. If a more precise adjustment is de- sired, the best procedure would be to push-in the pin corresponding to the up- coming hour (in this example, the 2 PM pin) and on that hour, slowly rotate the...
  • Page 6 To make sure the RC-4Bi will not start another cy- cle when the combined running time of stations 1 through 4 is less than 20 minutes, the con-...
  • Page 7 THANK YOU for your expression of confidence in Rain Bird Sprinkler Mfg. Corp. As the world's leading manufacturer of irrigation systems and components, our efforts are directed to providing you with the finest quality products and components available today.