Advertisement
LNK™ Ready
Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates information considered important, but not hazard-related (e.g., messages relating to property damage).
SAFETY INSTRUCTIONS
Specific safety-related instructions or procedures are described.
NUMBERS define a series of steps for the user to follow in order to operate the controller.
NOTE: Notifies the user of important operating instructions related to controller functionality, installation or maintenance.
REPEAT: Indicates that a repetition of previous steps or actions may be required for further operation, or to complete a process.
Questions?
Call Rain Bird toll free Technical Support at 1-800-724-6247 (USA and Canada only)
We believe it is our responsibility at Rain Bird to develop products that use water efficiently.
Feature | Description |
Maximum Stations | 22 (with optional Station Modules) |
Master Valve or Pump Start Relay | Supported |
Start Times | 6 |
Programs | 4 |
Program Cycles | Custom Days, Odd, Even and Cyclic |
Permanent Days Off | By program |
Master Valve Control | On/Off per station |
Rain Delay | Supported |
Rain/Freeze Sensor | Supported |
Rain Sensor Control | Global or by station |
Seasonal Adjust | Global or by program |
Manual Watering Run | Yes |
Manual Program Run | Yes |
Manual Test All Stations | Yes |
Short Detect | Yes |
Delay Between Stations | Set by program |
Accessory Port | Yes (5 pin) |
Save & Restore Programming | Yes |
Station Advance | Yes |
LNK™ WiFi Module | Supported |
Flow Sensor | Supported |
Cycle+Soak™ | Supported in Rain Bird App via LNK™ WiFi Module |
The LNK™ WiFi Module allows remote connection to a Rain Bird ESP-ME3 Controller using an Apple® iOS® or Android™ compatible smart device. The mobile application allows remote access and configuration of one or more irrigation controllers.
* Apple is a trademark of Apple Inc, IOS is a trademark of Cisco Systems Inc, and Android is a trademark of Google LLC.
For more information on the LNK™ WiFi Module and the value this product can provide for your ESP-ME3 controller, please visit: http://wifi-pro.rainbird.com
LNK™ WiFi Module (sold separately)
Manage Sites Remotely
NOTE: Choose a suitable mounting location close to a 120VAC wall outlet.
NOTICE
The ESP-ME3 controller DOES NOT provide power for a pump. The relay must be wired according to manufacturer instructions.
Only the following Rain Bird pump start relay models are compatible with the ESP-ME3:
Description | Note | Model No. |
Universal Pump Relay | 110 volt only | PSR110IC |
Universal Pump Relay | 220 volt only | PSR220IC |
NOTE: Connection to pump and external power not shown. Refer to pump installation instructions.
NOTE: Install the flow sensor in the field according to the manufacturer's instructions.
Set the controller to obey or ignore a flow sensor.
When set to Sensor ON, automatic irrigation will be suspended per station if detected flow exceeds learned flow by more than 30%. When set to Sensor OFF, all stations will ignore the flow sensor.
Turn the dial to Flow Sensor.
Sensor ON
Sensor OFF
Flow detected (flashing)
NOTE: When switching from Sensor OFF to Sensor ON, the controller will begin to LEARN FLOW. It will run each station for short period to set the expected station flow.
NOTE: See Troubleshooting section of the Appendix for Flow Alarms information.
Do not route the rain sensor wires through the same opening as the power wiring
NOTE: Rain Bird ESP-ME3 controllers are only compatible with normally closed rain sensors.
NOTE: For wireless rain/freeze sensors, refer to the sensor installation instructions.
Set the controller to obey or ignore a weather sensor.
When set to Sensor ON, automatic irrigation will be suspended if rainfall is detected. When set to Sensor OFF all stations will ignore the rain sensor.
Turn the dial to Weather Sensors.
Sensor ON
Sensor OFF
Rain detected (flashing)
DO NOT plug in the transformer or connect external power until you have completed and checked all wiring connections.
Electric shock can cause severe injury or death. Make sure power supply is turned OFF before connecting power wires.
POWER WIRING CONNECTIONS 120VAC
Black supply wire (hot) to the black transformer wire
White supply wire (neutral) to the white transformer wire
Green supply wire (ground) to the green transformer wire
Optional Station Modules can be installed in the empty slots to the right of the Base Module to increase the station capacity up to 22 stations.
NOTE: 6-Station Modules are compatible with ESP-ME3 and ESP-Me. They are not backwards compatible with the ESP-M vintage controller.
NOTE: For ideal station sequencing, insert 3-Station module after inserting all 6-station modules. For more details see the Station Numbering section.
REPEAT for additional modules.
NOTE: Modules can be installed or removed with OR without AC power connected. They are considered "hot-swappable".
NOTE: It take about 30 seconds for stations to become available for configuration after installing a new module.
The controller is configured with "fixed station numbering", meaning that Bays Two, Three and Four can accept either a 3 or a 6-Station Module. If a 6-Station Module is NOT installed then the unused stations are reserved for future use.
Example of Station Numbering when using two 3-Station Modules. A total of 10 stations are installed.
During programming, the controller will skip any unused stations, creating a gap in station numbering. The unused stations will show on the display as 8SKIP, 9SKIP, etc.
If the screen displays 20NOMOD where the 20 is flashing, then there is no module installed for that station number.
NOTE: The electrical connections can be checked even if water is not available. If water is available and you would like to test some or all of your stations, use the Test All Stations feature of the controller.
AUTO is the normal operating mode. Return the dial to AUTO when programming is complete.
During Watering:
The display shows a blinking sprinkler symbol, the active Station Number or Program, and the Remaining Run Time.
To Manually Start a Program:
Turn the dial to OFF to stop automatic irrigation or to cancel all active watering immediately.
NOTICE
Watering will NOT occur if the controller remains in the OFF position.
NOTE: Manual watering can be started using mobile apps or LIMR when dial is in OFF position.
Display | Function | Description |
![]() | ALL | All stations |
![]() | CLEARED | Programming was cleared |
![]() | CYCLIC | Watering occurs at specific intervals, such as every 2 days |
![]() | DELAY | Delay Watering Active |
![]() | EVEN | Even days watering |
![]() | FLOW | Flow Sensor |
![]() | MV ON | Master or Pump-start relay is active |
![]() | NOMOD | No station modules installed for that station |
![]() | ODD | Odd days watering |
![]() | OFF | Controller will not water |
![]() | PERMOFF | Permanent days off for Odd, Even, Cyclic watering |
![]() | RAIN | Rain Sensor |
![]() | RESTORD | Programming restored |
![]() | SAVED | Save programming |
![]() | SENS ON | Sensor will function if wired |
![]() | SEN OFF | Sensor is ignored even if wired |
![]() | SKIP | Station not used due to station module configuration |
![]() | SOAK | Soak time between watering times - supported through the Rain Bird app. |
Turn the dial to Date / Time
Up to six Start Times are available for each program.
Turn the dial to Start Times
NOTE: The OFF Position for any start time is between 11:45 PM and 12:00 AM.
Run Times can be set from one minute up to six hours.
Turn the dial to Run Times
NOTE: Only assign Run Times in a Program for stations you want to water. If you do not want a specific station to run in a selected program then set the Run Time to zero.
NOTE: Rain Bird recommends that the maximum irrigation station cycle time be less than the time required for runoff to begin and that there be adequate soak time before the next irrigation cycle of that same station begins again.
Set watering to occur on specific days of the week.
Turn the dial to Water Days
NOTE: With Sunday selected, press the
button to enter and activate Cyclic Watering (see the Advanced Programming section). If this is not desired, press the
button to return to watering by Custom Days.
The ESP-ME3 uses a programmed-based scheduling method to create irrigation schedules. This means all stations with a run time on the program will run in numerical order.
The most common programming error for any program-based controller is to set multiple Program Start Times that cause watering cycles to repeat.
As an example: Program A has a 1st Start Time set to run at 8:00 AM. But then a 2nd Start Time has mistakenly been set for 8:15 AM, which means that all stations would water a 2nd time.
In this example, a 3rd Start Time has mistakenly been set for 8:30 AM. Which means all stations would water a 3rd time. The desired watering time was 45 minutes, or 15 minutes per station. The actual is 2 hours and 15 minutes, which is excessive watering!
Incorrect: Multiple Start Times set by mistake
Program Letter | Program Watering Time | Program Start Time | Station Number | Station Watering Duration |
A | 1st | 8:00 AM | 1 | 15 MIN |
2 | 15 MIN | |||
3 | 15 MIN | |||
A | 2nd | 8:15 AM | 1 | 15 MIN |
2 | 15 MIN | |||
3 | 15 MIN | |||
A | 3rd | 8:30 AM | 1 | 15 MIN |
2 | 15 MIN | |||
3 | 15 MIN |
Correct: Only one Start Time
Program Letter | Program Watering Time | Program Start Time | Station Number | Station Watering Duration |
A | 1st | 8:00 AM | 1 | 15 MIN |
2 | 15 MIN | |||
3 | 15 MIN | |||
4 | 15 MIN |
Start watering immediately for all programmed stations.
Turn the dial to Manual Watering
Start watering a single station, or set multiple stations to water in order.
Turn the dial to Manual Watering
REPEAT process as desired to add more stations to the queue. When one station finishes watering then the next station will start.
NOTE: Manual Watering (Test All, Run Single Station and Manual Program) will start even when a weather sensor is set to SENS ON (sensor on).
Start watering immediately for one program.
Turn the dial to AUTO.
During Manual Watering (Single-station or Single-program):
The display shows a blinking sprinkler symbol, the active Station Number, and the remaining Run Time.
To add additional programs to the manual watering queue:
Turn the dial to Manual Watering
Set watering to occur on all ODD or EVEN calendar days.
Turn the dial to Water Days
Set watering to occur at specific intervals, such as every 2 days, or every 3 days, etc.
Turn the dial to Water Days
NOTE: See Special Features to set Rain Sensor ON by Station.
Increase or decrease program run times by a selected percentage (5% to 200%).
As an example: If the Seasonal Adjust is set to 100% and the station Run Time is programmed for 10 minutes, the station will run for 10 minutes. If the Seasonal Adjust is set to 50%, the station will run for 5 minutes.
Turn the dial to Seasonal Adjust.
Suspend watering for up to 14 days.
Turn the dial to AUTO.
NOTE: When the delay expires, automatic irrigation resumes as scheduled.
Prevent watering on selected days of the week (for Odd, Even or Cyclic programming only).
Turn the dial to Water Days
If the controller is not working properly, you can try pressing RESET.
A 5 pin accessory port is available for Rain Bird approved external devices, including:
Program the front panel remotely on battery power.
The front panel can be removed from the controller and programmed remotely using a 9 volt battery for power. Settings can be programmed for all 22 stations regardless of which Station Modules are installed in the controller.
If the display repeatedly shows "-- -- -- -- --", or there is no display when using a 9V battery for remote programming, replace the battery.
The ESP-ME3 controller has built-in error detection that can automatically generate an ALARM caused by an essential programming error or if an electrical short condition is detected.
The ALARM LED light on the ESP-ME3 controller front panel will light up to indicate an alarm condition:
Error | ALARM LED | Error Message On Display |
No Start Times are set | BLINK | NO START TIMES |
No Run Times are set | BLINK | NO RUN TIMES |
No Water Days are set | BLINK | NO WATER DAYS |
The error will go away when the station is successfully run after condition is corrected.
NOTE: The dial must be in the AUTO position for an ALARM message to appear on the display.
Error | ALARM LED | Error Message On Display |
Master Valve short | SOLID | MASTER VALVE SHORTED OR HIGH CURRENT |
Station short | SOLID | STATION "X" WIRE SHORTED |
When an electrical error is detected, irrigation for the affected station is cancelled and watering advances to the next operable station in the program.
The controller will attempt to water the affected station again at the next scheduled watering. Completion of a successful watering will clear the error condition associated with that station.
Error | ALARM LED | Error Message On Display |
Flow Sensor - High Flow Condition | Solid | HIGH FLOW ALARM STATION "X" |
Flow Sensor - Low Flow Condition | Solid | LOW FLOW ALARM STATION "X" |
When a flow sensor is in use the ESP-ME3 monitors for High Flow of 130% above regular learned flow. This percent limit can be adjusted in the Rain Bird App when used with LNK™ WiFi Module. If a High Flow condition is detected, a "High Flow Alarm" is shown at the display and the red alarm LED comes on. To clear the alarm press the "Hold to Start" right arrow button during the alarm message.
Low Flow conditions are also monitored. The limit for Low Flow is 70% below the learned flow unless changed in the Rain Bird App. A Low Flow alarm is shown at the controller display and the red alarm LED comes on.
To clear the alarm press the "Hold to Start" right arrow button during the alarm message.
NOTE: Turning the flow sensor feature off and then back on will cause the controller to learn new flow levels and ignore previous error conditions.
NOTE: If the flow sensor measures flow when the controller is not scheduled for watering, a "HIGH FLOW ZONE" alarm is shown on the display and the red alarm LED comes on. To clear the alarm press the "Hold to Start" right arrow button during the alarm message.
Problem | Possible Cause | Possible Solution |
Display shows a program is active, but system isn't watering. | Water source not supplying water. | Verify there is no disruption to the main water line and that all other water supply lines are open and functioning properly. |
Wiring is loose or not properly connected. | Check that field wiring and master valve or pump start relay wiring is securely connected at the controller and in the field. | |
Field wires are corroded or damaged. | Check field wiring for damage and replace if necessary. Check wiring connections and replace with watertight splice connectors if needed. | |
Loss of AC power. | When there is a power loss and a 9 volt battery is installed, the system does not irrigate but programs show as remaining active. | |
NO AC message on display. | No Power detected. | Check circuit breaker and that unit is plugged into socket or properly connected to power source. |
Controller may be plugged into a GFCI outlet or an outlet that is wired to a GFCI outlet. | Check power to the outlet or reset the circuit breaker. | |
It just rained and the alarm light is not illuminated, why? | This is normal operation. The ESP-ME3 does not consider the interruption of irrigation due to rainfall as an alarm condition. | This is normal operation. |
Programmed schedules do not start. | Connected rain sensor may be activated. | Set Rain Sensor to Sensor OFF to ignore the rain sensor. If watering resumes, the sensor is operating properly and no further correction is needed. |
Connected rain sensor may not be operating properly. | Let the rain sensor dry out, or disconnect it from the controller terminal strip and replace it with a jumper wire connecting the two SENS terminals, or set to Sensor OFF. | |
If no rain sensor is connected, the jumper wire connecting the two SENS terminals on the terminal strip may be missing or damaged. | Move dial position to Weather Sensors and set to Sensor OFF. | |
Too much irrigation | Multiple Start Times in the same program. | Separate start times are not required for each valve. A program only requires single start time in order to run all stations in that program. |
Multiple programs are running at the same time. | Review programming to assure that the same Station is not active in multiple Programs. | |
Valve is malfunctioning. | Check to see if the ALARM light on the controller is lit solid, then repair or replace the valve if necessary. | |
Seasonal Adjust setting is too high. | Set Seasonal Adjust to 100%. |
Problem | Possible Cause | Possible Solution |
Display is blank or frozen, the controller will not accept programming or is operating abnormally. | Power not reaching the controller. | Verify the main AC power supply is securely plugged in or connected and working properly. |
Controller needs to be reset. | Press the Reset Button. For details see "Reset Button" section. | |
An electrical surge may have interfered with the controller's electronics. | Unplug the controller for 2 minutes, then plug it back in. If there is no permanent damage, the controller should accept programming and resume normal operation. | |
Automatic error detection indicates a problem by ALARM LED and an error message on display. | Short circuit or overload condition in valve, master valve or pump start relay wiring. | Identify and repair the fault in the wiring. Refer to compatible pump start relays. For details see "Connect Pump Start Relay" section. |
LED is flashing or solidly illuminated but I see no message on the LCD. | Dial not in AUTO RUN position. | Turn dial to AUTO RUN position. Push Reset button or power cycle the controller. |
Supplier's Declaration of Conformity 47 CFR § 2.1077 Compliance Information
Unique Identifier: ESP-ME3 (ESP4ME3)
Responsible Party – U.S. Contact Information
Rain Bird Corporation
9491 Ridgehaven Court
San Diego, CA
92123
Ph. (858) 268-2650
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Special precautions must be taken when valve wires (also known as station or solenoid wires) are located adjacent to, or share a conduit with other wires, such as those used for landscape lighting, other "low voltage" systems or other "high voltage" power.
Separate and insulate all conductors carefully, taking care not to damage wire insulation during installation. An electrical "short" (contact) between the valve wires and another power source can damage the controller and create a fire hazard.
All electrical connections and wiring runs must comply with local building codes. Some local codes require that only a licensed or certified electrician can install power. Only professional personnel should install the controller. Check your local building codes for guidance.
Outdoor controller shall be permanently connected to fixed wiring by a flexible cord, and have a cord anchorage. The cord anchorage shall relieve conductors from strain, including twisting, at the terminals and protect the insulation of the conductors from abrasion.
Stationary appliances not fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage category III, the instructions state that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
For controllers not provided with supply cord, the fixed installation must include a disconnecting device for all three poles suitable for overvoltage category III protection.
NOTICE
Use only Rain Bird approved accessory devices. Unapproved devices may damage the controller and void the warranty. For a list of compatible devices go to: www.rainbird.com
NOTICE
Changes or modifications not expressly approved by Rain Bird could void the user's authority to operate the equipment.
NOTICE
Date and time are retained by a lithium battery which must be disposed of in accordance with local regulations.
The Intelligent Use of Water®
LEADERSHIP · EDUCATION · PARTNERSHIPS · PRODUCTS
At Rain Bird, we believe it is our responsibility to develop products and technologies that use water efficiently. Our commitment also extends to education, training and services for our industry and community.
The need to conserve water has never been greater. We want to do even more and with your help we can. Visit www.rainbird.com for more information about The Intelligent Use of Water®.
Rain Bird Corporation
6991 East Southpoint Road
Tucson, AZ 85756
USA
Tel: (520) 741-6100
Rain Bird Turkey
Çamlık Mh. Dinç Sokak Sk. No.4 D:59-60
34760 Ümraniye, İstanbul
TÜRKIYE
Tel: (90) 216 443 75 23
rbt@rainbird.eu
www.rainbird.com.tr
Rain Bird Ibérica S.A.
C/ Valentín Beato, 22 2ª Izq. fdo
28037 Madrid
ESPAÑA
Tel: (34) 91 632 48 10
rbib@rainbird.eu · www.rainbird.es
portugal@rainbird.eu
www.rainbird.pt
Rain Bird Corporation
970 W. Sierra Madre Ave.
Azusa, CA 91702
USA
Tel: (626) 812-3400
Rain Bird Europe SNC
Rain Bird France SNC
240 rue René Descartes
Bâtiment A, parc Le Clamar
BP 40072
13792 AIX-EN-PROVENCE CEDEX 3
FRANCE
Tel: (33) 4 42 24 44 61
rbe@rainbird.eu · www.rainbird.eu
rbf@rainbird.eu · www.rainbird.fr
Rain Bird Australia Pty Ltd.
Unit 13, Level1
85 Mt Derrimut Road
PO Box 183
Deer Park, VIC 3023
Tel: 1800 724 624
info@.rainbird.com.au
www.rainbird.com/au
Technical Services for U.S. and Canada only:
1 (800) RAINBIRD
1-800-247-3782
www.rainbird.com
Rain Bird International
1000 W. Sierra Madre Ave.
Azusa, CA 91702
USA
Tel: +1 (626) 963-9311
Rain Bird Deutschland GmbH
Königstraße 10c
70173 Stuttgart
DEUTSCHLAND
Tel: +49 (0) 711 222 54 158
rbd@rainbird.eu
Rain Bird Brasil Ltda.
Rua Marques Póvoa, 215
Bairro Osvaldo Rezende
Uberlândia, MG, Brasil
CEP 38.400-438
Tel: 55 (34) 3221-8210
www.rainbird.com.br
® Registered trademark of Rain Bird Corporation
© 2020 Rain Bird Corporation
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the ESP-ME3 and is the answer not in the manual?
Questions and answers