Parameter Description
Index:
P0719[0] : 1st. Command data set (CDS)
P0719[1] : 2nd. Command data set (CDS)
P0719[2] : 3rd. Command data set (CDS)
Note:
Using parameter P0719, it is possible to select the command or setpoint sources without changing the BICO
connections (this is contrary to P0700 / P1000). However, it is not possible to change the complete
connection table (refer to P0700 and P1000). Using P0719, depending on the value, only the BICO
parameters listed in the following table are internally overwritten - this means that these BICO parameters
are inactive.
Command source:
P0840
P0844
P0848
P0852
P1035
P1036
P1055
P1056
P1113
P1140
P1141
P1142
P1143
Setpoint source :
P1070
X =
BICO parameter active
− =
BICO parameter inactive
BICO connections made previously remain unchanged.
r0720

Number of digital inputs

P-Group: COMMANDS
Displays number of digital inputs.
r0722

CO/BO: Binary input values

P-Group: COMMANDS
Displays status of digital inputs.
Bitfields:
Bit00
Digital input 1
Bit01
Digital input 2
Bit02
Digital input 3
Bit03
Digital input 4
Bit04
Digital input 5
Bit05
Digital input 6
Bit06
Digital input 7 (via ADC 1)
Bit07
Digital input 8 (via ADC 2)
Note:
Segment is lit when signal is active.
82
P0719 =
0 ... 9
10 ... 19
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
P0719 =
0, 10, 20, 40, 50, 60
X
Datatype: U16
Datatype: U16
40 ... 49
50 ... 59
all other values
Min:
Unit: -
Def:
Max:
Min:
Unit: -
Def:
Max:
0
OFF
0
OFF
0
OFF
0
OFF
0
OFF
0
OFF
0
OFF
0
OFF
MICROMASTER 440
Issue 01/06
60 ... 69
Level
-
3
-
-
Level
-
2
-
-
1
ON
1
ON
1
ON
1
ON
1
ON
1
ON
1
ON
1
ON
Parameter List
6SE6400-5BB00-0BP0

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MICROMASTER 440 and is the answer not in the manual?

Questions and answers

LALIT SHARMA
April 4, 2025

how to check running motor kw in micromaster 440

1 comments:
Mr. Anderson
April 4, 2025

To check the running motor kW in the Siemens MICROMASTER 440, you need to monitor the actual motor power parameter during operation. This value is not directly listed in the provided context, but typically, the drive calculates and displays actual motor power in real-time through specific diagnostic parameters.

Use the operator panel or connected software to access diagnostic parameters where actual motor power is shown. Look for parameters related to motor power output, often found in the diagnostic or monitoring section of the drive interface.

Exact parameter numbers for real-time motor kW are not provided in the context, so refer to the drive's diagnostic menu or manual for the actual parameter displaying running kW.

This answer is automatically generated

Table of Contents