- 1x3HP Hydromassage pumps
- Energy-efficient LAING circulation pump
- 47 jets
- Hot air blower pump
- Ozone generator to water sanitzer
- Exclusive colour LED light therapy
Version: 01.2014
www.wellis.eu

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SAMOA and is the answer not in the manual?

Questions and answers

Summary of Contents for Wellis SAMOA

  • Page 1 USER MANUAL SAMOA SPA SYSTEM - 1x3HP Hydromassage pumps - Energy-efficient LAING circulation pump - 47 jets - Hot air blower pump - Ozone generator to water sanitzer - Exclusive colour LED light therapy Version: 01.2014 www.wellis.eu...
  • Page 2 Standard Specification Dimensions: 2000 x 1900 x 850 mm Shell material: PU reinforced acrylic 6,3mm Sitting places: 4 persons Reclining places: 1 person Water volume: 900 l Net weight: 280 kg Power requirement: 1 x 25A (230V) optimum 1 x 16A (230V) minimum Total number of jets: 47 pc Hydromassage pump:...
  • Page 3 5 year on spa shell: Wellis warrants the structure of the Pool Shell against defects in workmanship and material for a period of 5 years, subject to the limitations and conditions listed in this Warranty.
  • Page 4 1 year on Wellis Spa Umbrella: The factory installed Wellis Spa Umbrellas are warranted against failure due to defects in materials or workmanship for one year from the original date of delivery.
  • Page 5 Wellis Magyarország Kft. shall not be liable for any incidental or consequential damages for breach of any expressed or implied warranty, breach of contract, negligence, strict liability, or any other legal theory related to this product.
  • Page 6 It is obligatory to observe all information, details and requirements which are in the product`s installation diagram regarding elelectricity demand and drain installation. These information can be found in the user manual, or able to download from www.wellis.eu. If you didn`t get the document from your dealer, please contact export@wellis.eu.
  • Page 7 12 months, for the purpose of assessing Wellis Magyarország Kft. liability, all aspects covered by this Warranty will be treated on a pro-rata basis. Wellis Magyarország Kft. or its agents will not be liable for any incidental or consequential loss or injury. Nor will Wellis Magyarország Kft.be liable for costs associated with but not limited to building alterations or finishes and under no circumstances will be liable for greater expense than the amount paid for the product.
  • Page 8 SERVICE-WORK The announcement date of damage: _____________________________ Date of received goods/parts for repair: _____________________________ Date of the return of repaired goods/parts: ____________________________ Date of site service: _____________________________ STAMP Improved error: _____________________________ Mode of repair: _____________________________ Failed component: _____________________________ New deadline for the warranty: __________________________ The announcement date of damage: _____________________________...
  • Page 13 3.Clean with high pressure nozzle to remove all debris clinging to the filter. 4.Soak filter in warm water and Wellis Alga-Sokk to remove all body oils and grime. Never use chlorine to clean the filter! If you use textile filter, you can wash it...
  • Page 14 The chemical equilibrium of the water The water of the whirlpool will be clean and clear if its chemical components are in equilibrium. 1. pH-values: The first important indicator is the pH value of the water. pH is measured in a scale between 0-14 where 7 is the neutral value.
  • Page 15 TROUBLESHOOTING...
  • Page 17 Samoa Spa system BALBOA TP600 HOT TUB Control panel Main screen NAVIGATION Navigating the entire menu structure is done with 2 or 3 buttons on the control panel. Panels that have two Temperature buttons (Warm and Cool) can use both of them to simplify navigation and programming where a single Temperature icon is shown.
  • Page 18: Power-Up Screens

    POWER-UP SCREENS Each time the System powers up, a series of numbers is displayed. After the startup sequence of numbers, the system will enter Priming Mode. PREPARATION AND FILLING Fill the spa to its correct operating level. Be sure to open all valves and jets in the plumbing system before filling to allow as much air as possible to escape from the plumbing and the control system during the filling process.
  • Page 19: Exiting Priming Mode

    PRIMING MODE – M019* This mode will last for 4-5 minutes or you can manually exit the priming mode after the pump(s) have primed. *M019 is a Message Code. Regardless of whether the priming mode ends automatically or you manually exit the priming mode, the system will automatically return to normal heating and filtering at the end of the priming mode.
  • Page 20: Filtration And Ozone

    FILTRATION AND OZONE On non-circ systems, Pump 1 low and the ozone generator (if there is one) will run during filtration. On circ systems, the ozone will run with the circ pump. The system is factory-programmed with two filter cycles that will run 10 minutes after power-up. The filter duration is programmable.
  • Page 21: Circulation Mode

    In order for the spa to heat, a pump needs to circulate water through the heater. The pump that performs this function is known as the “heater pump.” The heater pump can be either a 2-Speed Pump 1 or a circulation pump. If the heater pump is a 2-Speed Pump 1, READY Mode will circulate water every 1/2 hour, using Pump 1 Low, in order to maintain a constant water temperature, heat as needed, and refresh the temperature display.
  • Page 22: Flip (Invert Display)

    FLIP (INVERT DISPLAY) Note: Some panels may have a dedicated FLIP button, which allows the user to flip the display with a single button-press. The FLIP menu/functionality depends on Manufacturer configuration and may not be available. (Menu Style 1) MAIN FILTRATION Filter cycles are set using a duration.
  • Page 23: General Messages

    GENERAL MESSAGES Priming Mode – M019 Each time the spa is powered up, it will enter Priming Mode. The purpose of Priming Mode is to allow the user to run each pump and manually verify that the pumps are primed (air is purged) and water is flowing.
  • Page 24: Heater-Related Messages

    HEATER-RELATED MESSAGES Heater Flow is Reduced (HFL) – M016 There may not be enough water flow through the heater to carry the heat away from the heating element. Heater start up will begin again after about 1 min. See “Flow Related Checks” below. Heater Flow is Reduced (LF)* –...
  • Page 25: Sensor-Related Messages

    SENSOR-RELATED MESSAGES Sensor Balance is Poor – M015 The temperature sensors MAY be out of sync by 2°F or 3°F. Call for Service. Sensor Balance is Poor* – M026 The temperature sensors ARE out of sync. The Sensor Balance is Poor fault has been established for at least 1 hour.
  • Page 26: System-Related Messages

    SYSTEM-RELATED MESSAGES Memory Failure - Checksum Error* – M022 At Power-Up, the system has failed the Program Checksum Test. This indicates a problem with the firmware (operation program) and requires a service call. Memory Warning - Persistent Memory Reset* – M021 Appears after any system setup change.
  • Page 27: Reminder Messages

    REMINDER MESSAGES General maintenance helps Reminder Messages can be suppressed by using the PREF Menu. Reminder Messages can be chosen individually by the Manufacturer. They may be disabled entirely, or there may be a limited number of reminders on a specific model. The frequency of each reminder (i.e.
  • Page 28 Appears on a regular schedule, e.g. every 90 days. Change the water in the spa on regular basis to maintain proper chemical balance and sanitary conditions. Alternates with temperature or normal display. Appears on a regular schedule, e.g. every 180 days. Vinyl covers should be cleaned and conditioned for maximum life.
  • Page 29 Warning! Qualified Technician Required for Service and Installation Basic Installation and CSA Compliance/Conformité Caution: Configuration Guidelines Use minimum 6AWG copper conductors only. Torque field connections between 21 and 23 in lbs. Readily accessible disconnecting means to be provided at time of instal- in a pit.
  • Page 30 Piping instructions of SAMOA spa 30mA safety relay is need to be installed! E: Electric hole ( 800 mm) to terminal facilities through spa cabinet. 3 m cabels are required!  L : Drain connector ( 30 0 mm) ...
  • Page 31 1 Phase (Line) Connection to 1x16A (minimum) Advice to SAMOA modell...