2.6 EXTERNAL BATTERY CONNECTION (Figure 2-4)

It is recommended that an external battery should be installed to back up the system in case of AC
power failure. The DCS-816 system is equipped with battery charging and discharging circuits to
interface with an external battery.
To decide the capacity of the battery, keep in mind that it may damage the system if too large while
it cannot back up the system long enough if too small. The capacity should not be less than 6AH
or more than 26AH. The battery voltage should be 48 volts.
To connect an external battery, first pick out the battery connection cable through the MDF cable
path. Connect the RED lead of the cable to the positive (+) terminal of the battery and the BLACK
lead to the negative (-) terminal. Then insert the housing connector into the header in the power
supply.
NOTE: The actual connection should be done as the final step in the installation of the KSU.

CONNECTING A SYSTEM BACKUP BATTERY

USE EXTREME CAUTION ON
THE POLARITY AND THE IN-
RUSH CURRENT AT THE
POINT OF CONNECTION