General Information Cyclical Display; Basic Information Menu; Main Menu - Statistics - ABB CDD Product Manual

Concentrator data device
Table of Contents

Advertisement

GENERAL INFORMATION cyclical display

Total output power level of the MICRO Inverters that make up the plant
Total energy produced by the plant from the time it is put into operation
Plant quality expressed as a percentage and labeled Low, Medium, or High
MICRO: X = number of inverters in the plant
EXTRA: Y = number of inverters over limit of 30
Alarm status displays presence or absence of alarms, see section 7 for alarm codes
Date and time set on the CDD, use CHANGE SETTINGS menu to modify values
WLess strength of network connection, represented by 1 to 4
Press any button while in the GENERAL INFORMATION display to view the BASIC
information described below. Use the UP and DOWN buttons to scroll through the list.
BASIC information and options
Web Server IP address used to access the local web server of the CDD
MAC Addr. WLess address relating to the CDD
Subnet Mask address relating to internet
IP Gateway address used to send data of the monitored plant
Primary DNS primary address of internet domain name server
Secondary DNS secondary address of internet domain name server
Wless Enabled, Yes > wireless connectivity is enabled by default
Press ENTER to remove arrow >, press DOWN to scroll to NO, press
ENTER to select NO and disable wireless connectivity
Wless AutoConn., Yes > auto connection to last network connected is
recommended and enabled by default; press ENTER to remove arrow >,
press DOWN to scroll to NO, press ENTER to select NO and disable
Web Server, Reset Password? default password (admin) of the local web
server can be reset, press ENTER to reset
Wless SSID: name of connected wireless network
To access the MAIN menus described below and continued on next page, press and hold
the UP and DOWN buttons until the Set Password screen appears; default password is 0010.
Scroll UP or DOWN to select a number and press ENTER to accept each digit.
MAIN menus
Statistics of the system and each inverter
Tot output power level of the inverters that make up the plant
Total Energy produced by the plant from the time it is put into operation
Inverter data > press ENTER to view
# microinverter displays the total number of inverters in the plant
SN xxxxxx > lists each inverter by serial number; scroll DOWN list
of inverters, press ENTER to select inverter and view following data:
View Information read only display
Change Settings modify CDD settings and acquire inverters
Total Energy
Input Voltage
Output Power
DSP Release
Micro Release
Model ID
MAC Address
Output Current
Input Current
Output Voltage
Frequency
Temperature