Summary of Contents for National Instruments cRIO-9002
Page 1
National Instruments cRIO-9004 Manual Get Pricing & Availability at ApexWaves.com Call Today: 1-800-915-6216 Email: sales@apexwaves.com https://www.apexwaves.com/modular-systems/national-instruments/compactrio-controllers/cRIO-9004...
Page 2
2. Power Connector 5. RJ-45 Ethernet Port 3. DIP Switches 6. RS-232 Serial Port This document describes how to connect the cRIO-9002/9004 to a network and how to use the features of the cRIO-9002/9004. This document also contains specifications for the controllers.
NI for repair. Safety Guidelines for Hazardous Locations The cRIO-9002/9004 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx nA IIC T4 and Ex nA IIC T4 hazardous locations;...
Page 5
Complete the following steps to install the controller on the chassis. Make sure that no power is connected to the controller or the chassis. Align the controller with the chassis as shown in the following figure. 4 | ni.com | NI cRIO-9002/9004 User Manual and Specifications...
Page 7
The cRIO-9002/9004 draws power from the power source with the higher voltage. The cRIO-9002/9004 has one layer of reversed-voltage protection. The power source you connect to the cRIO-9002/9004 must provide an additional layer of reversed-current flow protection. Complete the following steps to connect power sources to the cRIO-9002/9004.
Page 9
Connecting Serial Devices to the cRIO-9002/9004 The cRIO-9002/9004 has an RS-232 serial port to which you can connect devices such as displays or input devices. Use the Serial VIs to read from and write to the serial port from a LabVIEW Real-Time application.
Keep this switch in the OFF position during normal operation. If the switch is in the ON position at startup, the cRIO-9002/9004 launches only the essential services required for updating its configuration and installing software. The LabVIEW Real-Time engine does not launch.
2. BACKUP 4. USER1 POWER LED The POWER LED is lit while the cRIO-9002/9004 is powered on. This LED indicates that the power supply connected to the chassis is adequate. BACKUP LED The Backup LED is lit when the controller is drawing power from the V2 terminal.
The following specifications are typical for the range -40 °C to 70 °C unless otherwise noted. Caution Do not operate the cRIO-9002/9004 in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way.
1,253,788 hours at 25 °C; Bellcore Issue 6, Method 1, Case 3, Parts Count Method Power Requirements You must use a National Electric Code (NEC) Class 2 power source with the cRIO-9002/9004. Recommended power supply 48 W secondary, 18 VDC to 24 VDC...
MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV. Caution Do not connect the cRIO-9002/9004 to signals or use for measurements within Measurement Categories II, III, or IV. Safety and Hazardous Locations Standards...
质指令(RoHS)。关于 National Instruments 中国 RoHS 合规性信息,请登录 。(For information about China RoHS ni.com/environment/rohs_china compliance, go to ni.com/environment/rohs_china Cabling The following table shows the standard Ethernet cable wiring connections for both normal and crossover cables. 16 | ni.com | NI cRIO-9002/9004 User Manual and Specifications...