1 Alarms
1.5.1 Alarm description
120017
Transmission aborted
Scan
The user has aborted data transfer with softkey.
Effect
The data have not been transferred or only incompletely.
Explanation
–
Remedy
Select another file, restart transmission.
Note
Applies as from SW 4.4
120018
Error in channel no. / TO area
Scan
The channel no. or TO area entered is not permissible with the NC source specified.
Effect
File is not transferred.
Explanation
None
Remedy
Correct number.
120019
Name ... not allowed
Scan
An illegal file name has been entered.
Effect
The file with the name is not created on the MMC side.
Explanation
Letters A...Z, numbers 0...9 and the underscore character are permissible.
Remedy
Please enter the correct name, e.g. ABC _123
120020
There is no data/part program
Scan
The error occurred while a file was being transferred.
Effect
File has not been transferred or only partially.
Explanation
–
Remedy
–
120021
Error in NCK name
Scan
The error occurred while a file was being transferred.
Effect
File has not been transferred or only partially.
Explanation
The name for the NC is incorrect. It consists of an NC identifier (RPA for R parameter) and the channel number,
e.g.: R parameter for channel 2 ! name = RPA2
Remedy
Correct the name and/or channel number
120022
No read/write access for ...
Scan
The error occurred while transferring a file.
Effect
File has not been transferred or only partially.
Explanation
–
Remedy
Set keyswitch for data.
120023
Memory on NC is full
Scan
An error occurred during transfer of a file.
Effect
File has not been transferred or only partially.
Explanation
The NC part program is full.
Remedy
If necessary, delete part programs from the memory.
1–126
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
04/96
OK softkey
OK softkey
OK softkey
OK softkey
OK softkey
OK softkey
OK softkey