OfficeServ 500 Wireless LAN Service Manual/Ed.00
3.2

Configuring the Console Terminal

The values of the console terminal to be used are configured as shown below.
Emulation : compatible with VT-100/ANSI
Bits per second : 9600 bps
Stop bit : 1
Data bit : 8
Parity bit : None
Flow control : None
The method of setting the console terminal can be different according to the terminal
type or the management system. The file(WLIROM.HEX, MWLIROM.HEX) is
loaded to the 8WLI card in the following two methods.
Using the Tera terminal of the Windows 95/98 operating system
Using the 'qmodem.exe' on the DOS window
3.2.1 Loading a File with the Tera Terminal
1) Turn on the PC(Windows95/98 O/S).
2) Execute the Tera terminal program
3) If console terminal is not connected, 'Cannot open COM1' message windows
appears. Then, Click the <file> <New Connection> to open the new window.
4) Select the <Setup> <Serial Port> from the new window, and set as shown
below then click the [Ok] button.
Bits per second : 9600 bps
Stop bit : 1
Data bit : 8
Parity bit : None
Flow control : None
5) Then a new Tera terminal will show up.
© SAMSUNG Electronics Co., Ltd.
CHAPTER 5. Maintenance
Page 5-19