CHAPTER 3. Installation
4
Connecting the 8WLI with the WBS24
When the cable with two twisted-pairs connecting the 8WLI and the WBS24 has the
common characteristics, the OfficeServ 500 System's wireless LAN offers good
performance.
Even when one of the two cable pairs is disconnected, the power will be supplied
normally, since the WBS24 uses the phantom feeding method for power supply.
This section describes the procedure for connecting the 8WLI, which is mounted on
the OfficeServ 500 System, with the WBS24, which is installed on a wall.
Preparing the Cable
Prepare a RJ-45 cable or two twisted-pair(4 wires) cables of the below specifications.
Item
Diameter
Length
Interface
Page 3-8
8WLI connector
8WLI
Figure 3.10 RJ-45 cable
Table 3.1 Twisted Pair cable specifications
0.6 mm or 0.4 mm
0.6mm in diameter and 600M or less in length, or 0.4 mm in diameter and
400 M or less in length.
2×U interface & 64 Kbit/sec via 4 B-channels
OfficeServ 500 Wireless LAN Service Manual/Ed.00
WBS24 connector
Cable Specifications
© SAMSUNG Electronics Co., Ltd.
WBS24