Negative Mvar Trip Delay
2210
Positive Mvar Trip Delay
2211
Positive Mvar Alarm Delay
POWER ELEMENTS / REVERSE POWER
2240
Block Reverse Power From Online
2241
Reverse Power Alarm
2242
Assign Alarm Relays (2-5)
2243
Reverse Power Alarm Level
2245
Reverse Power Alarm Delay
2246
Reverse Power Alarm Events
2247
Reverse Power Trip
2248
Assign Trip Relays (1-4)
2249
Reverse Power Trip Level
224B
Reverse Power Trip Delay
POWER ELEMENTS / LOW FORWARD POWER
2280
Block Low Forward Power From Online
2281
Low Forward Power Alarm
2282
Assign Alarm Relays (2-5)
2283
Low Forward Power Alarm Level
2285
Low Forward Power Alarm Delay
2286
Low Forward Power Alarm Events
2287
Low Forward Power Trip
2288
Assign Trip Relays (1-4)
2289
Low Forward Power Trip Level
228B
Low Forward Power Trip Delay
RTD TEMPERATURE / RTD TYPES
2400
Stator RTD Type
2401
Bearing RTD Type
2402
Ambient RTD Type
2403
Other RTD Type
RTD TEMPERATURE / RTD #1
2420
RTD #1 Application
2421
RTD #1 Alarm
2422
Assign Alarm Relays (2-5)
2423
RTD #1 Alarm Temperature
2424
RTD #1 Alarm Events
2425
RTD #1 Trip
2426
RTD #1 Trip Voting
2427
Assign Trip Relays (1-4)
2428
RTD #1 Trip Temperature
2429
RTD #1 Name
RTD TEMPERATURE / RTD #2
2460
RTD #2 Application
2461
RTD #2 Alarm
2462
Assign Alarm Relays (2-5)
2463
RTD #2 Alarm Temperature
2464
RTD #2 Alarm Events
2465
RTD #2 Trip
2466
RTD #2 Trip Voting
2467
Assign Trip Relays (1-4)
2468
RTD #2 Trip Temperature
2469
RTD #2 Name
RTD TEMPERATURE / RTD #3
1, 2, 3
See Table footnotes on page page 42
32
Table CG–1: 489 Memory Map (Sheet 20 of 30)
Name
RANGE
STEP
2 to 1200
1
2 to 1200
1
2 to 1200
1
0 to 5000
1
0 to 2
1
1 to 4
1
2 to 99
1
2 to 1200
1
0 to 1
1
0 to 2
1
0 to 3
1
2 to 99
1
2 to 1200
1
0 to 15000
1
0 to 2
1
1 to 4
1
2 to 99
1
× Rated MW
2 to 1200
1
0 to 1
1
0 to 2
1
0 to 3
1
2 to 99
1
× Rated MW
2 to 1200
1
0 to 3
1
0 to 3
1
0 to 3
1
0 to 3
1
0 to 4
1
0 to 2
1
1 to 4
1
1 to 250
1
0 to 1
1
0 to 2
1
1 to 12
1
0 to 3
1
1 to 250
1
0 to 8
1
0 to 4
1
0 to 2
1
1 to 4
1
1 to 250
1
0 to 1
1
0 to 2
1
1 to 12
1
0 to 3
1
1 to 250
1
0 to 8
1
489 GENERATOR MANAGEMENT RELAY – COMMUNICATIONS GUIDE
UNITS
FORMAT
DEFAULT
s
F2
10
s
F2
200
s
F2
100
s
F1
1
F115
0
F50
16
× Rated
F14
5
s
F2
100
F105
0
F115
0
F50
1
× Rated
F14
5
s
F2
200
s
F1
0
F115
0
F50
16
F14
5
s
F2
100
F105
0
F115
0
F50
1
F14
5
s
F2
200
F120
0
F120
0
F120
0
F120
0
F121
1
F115
0
F50
16
°C
F1
130
F105
0
F115
0
F122
1
F50
1
°C
F1
155
F22
_
F121
1
F115
0
F50
16
°C
F1
130
F105
0
F115
0
F122
2
F50
1
°C
F1
155
F22
_