Lan; Understanding; Configuring - GE MDS Master Station Technical Manual

Modular communications platform
Hide thumbs Also See for MDS Master Station:
Table of Contents

Advertisement

- After the last character of a transmission is output from the serial port, the unit
shall keep CTS asserted until the expiration of
CTSKEYPLUS
- The unit shall support flow control (Throttling) on the RTS pin. The device is ex-
pected to be wired via null modem to an external DCE device. The CTS line of
the external DCE device drives the RTS line of the unit.
Statistics for the Serial ports and IP Payload 1, 2, 3 are located under the active SD radio
interface (
Interfaces
terfaces" for more details.

5.7 LAN

Understanding

This section will cover only the basic configuration of Ethernet ports and bridges. For
full details on the configuration of more advanced features, please reference the MDS
Orbit MCR Technical Manual (05-6632A01)
The Master Station has external Local Area Network (LAN) ports (
used to connect to a local (wired) LAN. It supports both IPv4 and IPv6 addresses and may be
assigned multiple IP addresses. The LAN port can be assigned static IP addresses or a dynami-
cally allocated address can be assigned using DHCP.
The LAN port should be assigned IP addresses only if it is a routed interface (that is, not
in a bridge).

Configuring

To configure the LAN interface, select the eth-0/0/0 or eth-0/0/1. As shown in the screens below,
there are five groups of configuration settings that can be configured: General ETHx specifics,
IPV4, QOS, Filter, and NAT
Basic Config
Interfaces
eth-0/0/x
MDS 05-6399A01, Rev. E
sd-x/0/0
Status
Basic Config
MDS™ Master Station
CTS hold time
. See the section entitled "SD-x/0/0 In-
Statistics)
ETH1/2
.
ports) that can be
39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents