The RF safety distance is calculated based on each product type's highest output power
configuration with no duplexer, redundant switching, or cable losses.
Table 1-1 Antenna Gain vs. Minimum RF Safety Distance
Safety Distance
SDM4 variant - FCC
Safety Distance
SDM4 variant – IC
Safety Distance
SDM9 variant – FCC
Safety Distance
SDM9 variant - IC
Safety Distance
(other models):
Not all frequency models available. Consult factory for available models.
Antennas with gain greater than 16dBi have not been authorized for use with the EUT; and (b)
installation of the EUT into portable applications with respect to RF compliance will require
SAR testing and Regulatory approval.
CSA Notice
installation is subject to acceptance of CSA International or the local inspection authority having
jurisdiction.
6
Units (Both AC and DC supply versions) are permanently connected to
Protective Earth, via ground stud on the unit enclosure back, where the final
Conditions of Acceptability:
1.
The equipment shall be installed indoors in a restricted access location.
2.
Installation of the equipment and its modules shall be conducted by
trained personnel in accordance with the electrical code.
3.
This equipment is movable, Class I (earthed), pluggable Type A, using
detachable power cords, intended for use on TN or TT power system
for the AC power option.
4.
The DC power option shall be connected to an approved power source
with adequate protection, isolated from the mains by reinforced insu-
lation.
MDS™ Master Station
Antenna Gain
0–5 dBi
5–10 dBi
1.09 meters
1.95 meters
1.43 meters
2.54 meters
0.99 meters
1.76 meters
1.29 meters
2.30 meters
Consult factory prior to operation.
10–16.5 dBi
4.11 meters
5.37 meters
3.73 meters
4.87 meters
MDS 05-6399A01, Rev. E