Washing without detergent compartment
24
Dispensing calibration  Dispensing pump 1
V:
100 ml
t:
Press multifunction button 0/1 .
Stop the pump by pressing the 0/1 button, or it will stop automatically
after 60 seconds.
Measure the amount of liquid dispensed into the measuring vessel.
Dispensing calibration  Dispensing pump 1
V:
100 ml
t:
Enter the measured value into the "V:" field.
The throughput P is calculated in ml/min. by the controls.
Press the  "Save" button.
The measured value is allocated to the pump.
Reconnect the hose.
0 s
P: No
0/1
30 s
P: 200 ml/min
0/1