Eurotronic Spirit Z-Wave Plus Installation & Operation Manual

Eurotronic Spirit Z-Wave Plus Installation & Operation Manual

Energy-saving
Hide thumbs Also See for Spirit Z-Wave Plus:

Advertisement

EN
Spirit Z-Wave Plus
Installation & Operation Guide
Made in Germany
www.eurotronic.org

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Spirit Z-Wave Plus and is the answer not in the manual?

Questions and answers

Summary of Contents for Eurotronic Spirit Z-Wave Plus

  • Page 1 Spirit Z-Wave Plus Installation & Operation Guide Made in Germany www.eurotronic.org...
  • Page 2: Table Of Contents

    Buttons and Displays Multilevel Switch Buttons Notification Boost-Buttons LEDs Protection Thermostat Mode Network behavior Thermostat Setpoint Inclusion Mounting the Spirit Z-Wave Plus Troubleshooting Plus Mechanical Installation Exclusion Unmounting the Spirit Z-Wave Plus Factory Rese Operating the device Setpoint adjustment Child protection...
  • Page 3: Included In Delivery

    1. Included in delivery 1. Spirit Z-Wave Plus energy-saving controller 2. Screw 3. Adapters for Danfoss valves 4. 2x AA batteries When using the RAV adapter, you need the RAV Pin for the extension of the valve stem. RAV Pin*...
  • Page 4: Adapters

    1,0 mm, Vama M28 x 1,0 mm, Pettinaroli M28 x 1,5 mm, T+A M28 x 1,5 mm, Gampper 1/2/6. If you are not sure which valve you are using, please visit: www.eurotronic.org/Produkte/Adapter for fur- ther Information. Here you will find a list of various valves and adapters.
  • Page 5: Warranty

    Operate Spirit Z-Wave Plus only as described in the user manual. Spirit Z-Wave Plus should only be put to use in a dry and dust-free place, away from direct sunlight. Do not keep using the device when there is obvious damage.
  • Page 6: Buttons And Displays

    • Quit Boost-mode(Quick Heat) if currently active. Hold for 3 seconds The LCD shows the Z-Wave Node ID. Hold for 5 seconds The Spirit Z-Wave Plus will react to Exclusion Commands. Hold while unpowered and Allows factory reset of the Spirit Z-Wave Plus. insert batteries Hold both simultaneously Sets or clears the child protection.
  • Page 7: Lcd

    5 seconds Wrench: Lights up if mechanical tasks are ongoing. Antenna: Displays the Spirit Z-Wave Plus network state. Segment visible: rf-link established Segment turned off: rf-link lost ID: Lights up if the Display shows the Z-Wave NodeID. Battery: Lights up if less than 15% battery is remaining Lock: Lights up if child protection is set.
  • Page 8: Network Behavior

    Spirit Z-Wave Plus. Inserting batteries Remove the battery cover by simply pulling it off. Now insert the batteries. Pay attention to the correct polarity! At a later battery change, the configuration of your Spirit Z-Wave Plus is maintained. – 8–...
  • Page 9: Inclusion

    Inclusion Start Inclusion mode of your primary Z-Wave Controller. Press the Boost-Button. Spirit Z-Wave Plus will show the assigned NodeID. Inclusion Success Press blinking Joining in progress Joining successful. Boost button Received Node ID is display. after 5 sec. Mechanical installation required.
  • Page 10: Mounting The Spirit Z-Wave Plus

    Mounting the Spirit Z-Wave Plus After adding the Spirit Z-Wave Plus to a network it is ready to be installed on the radiator. The LCD shows INS. Do not press the boost button yet. If successfully installed to the radiator proceed with 4.6.
  • Page 11: Plus Mechanical Installation

    Mechanical Installation Press the boost button to start mechanical installation. Installation Mounting position Press Boost button Installation in is prepared. to start installation progress. Installation successful 22.0° Main screen with setpoint temperature. – 11–...
  • Page 12: Exclusion

    Press Boost button to clear error Exclusion Start Exclusion mode of your primary Z-Wave Controller. Now press and hold the boost button of the Spirit Z-Wave Plus for at least 5 seconds. Exclusion 22.0° Leave in progress. Press and hold for 5 sec.
  • Page 13: Unmounting The Spirit Z-Wave

    Unmounting the Spirit Z-Wave Plus Remove the Spirit Z-Wave Plus from the Z-Wave network before unmounting it. Follow the process described in Exclusion and wait until the LCD shows INC. You can now uninstall Spirit Z-Wave Plus from the radiator.
  • Page 14: Operating The Device

    Press and hold plus and minus button simultaneously for 3 seconds to enable/disable the child protection. If the Spirit Z-Wave Plus is set into the highest protection level it is no longer possible to operate the device locally. Altering the operating states Off-Mode Press minus button until OFF is displayed.
  • Page 15: Window Open Detection

    Window open detection If the roomtemperature drops the window open detection will trigger. Spirit Z-Wave Plus will change temporarily in off mode for 15 minutes. Window open detection will end automatically after 15 minutes and the previously active operating mode will be restored.
  • Page 16: Z-Wave

    U, S0, S2 Z-Wave Plus Info Identifies the device as a Z-Wave Plus Device. *Availability of the Command Class after adding the Spirit Z-Wave Plus to your Z-Wave network. U Unsecure S0 Z-Wave Security standard S0 S2 Z-Wave Security standard S2...
  • Page 17: Assoziation

    DEVICE_RESET_LOCALLY_NOTIFICATION, THERMOSTAT_MODE_REPORT, THERMOSTAT_SETPOINT_REPORT, NOTIFICATION_REPORT, PROTECTION_REPORT, SENSOR_MULTILEVEL_REPORT, SWITCH_MULTILEVEL_REPORT Basic Control basic functions of the Spirit Z-Wave Plus via basic command class. Value Description Function 0x00 Energy Save Switches into energy save heating mode. The room temperature will be lowered to Heating the configured setpoint in order to save.
  • Page 18: Configuration

    Configuration Spirit Z-Wave Plus can be configured during runtime. Parameter Size Name Description number in Byte LCD Invert 0x00 LCD-content normal 0x01 LCD-content inverted (UK Edition) default: 0x00 LCD Timeout 0x00 No Timeout LCD always on 0x05-0x1E LCD will turn off after 5 to 30 seconds.
  • Page 19: Multilevel Switch

    0x0F Full Power Switches into Boost mode (Quick heat). Spirit Z-Wave Plus heats the room up as fast as possible. The mode is left automatically after 5 minutes or earlier if requested by the user(via Z-Wave or locally on the device).
  • Page 20: Thermostat Setpoint

    Thermostat Setpoint The following setpoints of the Spirit Z-Wave Plus can be altered. Modus Name Precision Scale Temp. Range 0x01 Heat 0,1 and 2 Celsius and Fahrenheit 8°C-28°C 0x0B Energy Heat 0,1 and 2 Celsius and Fahrenheit 8°C-28°C 7 Troubleshooting...