1. Included in delivery 1. Spirit Z-Wave Plus energy-saving controller 2. Screw 3. Adapters for Danfoss valves 4. 2x AA batteries When using the RAV adapter, you need the RAV Pin for the extension of the valve stem. RAV Pin*...
1,0 mm, Vama M28 x 1,0 mm, Pettinaroli M28 x 1,5 mm, T+A M28 x 1,5 mm, Gampper 1/2/6. If you are not sure which valve you are using, please visit: www.eurotronic.org/Produkte/Adapter for fur- ther Information. Here you will find a list of various valves and adapters.
Operate Spirit Z-Wave Plus only as described in the user manual. Spirit Z-Wave Plus should only be put to use in a dry and dust-free place, away from direct sunlight. Do not keep using the device when there is obvious damage.
• Quit Boost-mode(Quick Heat) if currently active. Hold for 3 seconds The LCD shows the Z-Wave Node ID. Hold for 5 seconds The Spirit Z-Wave Plus will react to Exclusion Commands. Hold while unpowered and Allows factory reset of the Spirit Z-Wave Plus. insert batteries Hold both simultaneously Sets or clears the child protection.
5 seconds Wrench: Lights up if mechanical tasks are ongoing. Antenna: Displays the Spirit Z-Wave Plus network state. Segment visible: rf-link established Segment turned off: rf-link lost ID: Lights up if the Display shows the Z-Wave NodeID. Battery: Lights up if less than 15% battery is remaining Lock: Lights up if child protection is set.
Spirit Z-Wave Plus. Inserting batteries Remove the battery cover by simply pulling it off. Now insert the batteries. Pay attention to the correct polarity! At a later battery change, the configuration of your Spirit Z-Wave Plus is maintained. – 8–...
Inclusion Start Inclusion mode of your primary Z-Wave Controller. Press the Boost-Button. Spirit Z-Wave Plus will show the assigned NodeID. Inclusion Success Press blinking Joining in progress Joining successful. Boost button Received Node ID is display. after 5 sec. Mechanical installation required.
Mounting the Spirit Z-Wave Plus After adding the Spirit Z-Wave Plus to a network it is ready to be installed on the radiator. The LCD shows INS. Do not press the boost button yet. If successfully installed to the radiator proceed with 4.6.
Mechanical Installation Press the boost button to start mechanical installation. Installation Mounting position Press Boost button Installation in is prepared. to start installation progress. Installation successful 22.0° Main screen with setpoint temperature. – 11–...
Press Boost button to clear error Exclusion Start Exclusion mode of your primary Z-Wave Controller. Now press and hold the boost button of the Spirit Z-Wave Plus for at least 5 seconds. Exclusion 22.0° Leave in progress. Press and hold for 5 sec.
Unmounting the Spirit Z-Wave Plus Remove the Spirit Z-Wave Plus from the Z-Wave network before unmounting it. Follow the process described in Exclusion and wait until the LCD shows INC. You can now uninstall Spirit Z-Wave Plus from the radiator.
Press and hold plus and minus button simultaneously for 3 seconds to enable/disable the child protection. If the Spirit Z-Wave Plus is set into the highest protection level it is no longer possible to operate the device locally. Altering the operating states Off-Mode Press minus button until OFF is displayed.
Window open detection If the roomtemperature drops the window open detection will trigger. Spirit Z-Wave Plus will change temporarily in off mode for 15 minutes. Window open detection will end automatically after 15 minutes and the previously active operating mode will be restored.
U, S0, S2 Z-Wave Plus Info Identifies the device as a Z-Wave Plus Device. *Availability of the Command Class after adding the Spirit Z-Wave Plus to your Z-Wave network. U Unsecure S0 Z-Wave Security standard S0 S2 Z-Wave Security standard S2...
DEVICE_RESET_LOCALLY_NOTIFICATION, THERMOSTAT_MODE_REPORT, THERMOSTAT_SETPOINT_REPORT, NOTIFICATION_REPORT, PROTECTION_REPORT, SENSOR_MULTILEVEL_REPORT, SWITCH_MULTILEVEL_REPORT Basic Control basic functions of the Spirit Z-Wave Plus via basic command class. Value Description Function 0x00 Energy Save Switches into energy save heating mode. The room temperature will be lowered to Heating the configured setpoint in order to save.
Configuration Spirit Z-Wave Plus can be configured during runtime. Parameter Size Name Description number in Byte LCD Invert 0x00 LCD-content normal 0x01 LCD-content inverted (UK Edition) default: 0x00 LCD Timeout 0x00 No Timeout LCD always on 0x05-0x1E LCD will turn off after 5 to 30 seconds.
0x0F Full Power Switches into Boost mode (Quick heat). Spirit Z-Wave Plus heats the room up as fast as possible. The mode is left automatically after 5 minutes or earlier if requested by the user(via Z-Wave or locally on the device).
Thermostat Setpoint The following setpoints of the Spirit Z-Wave Plus can be altered. Modus Name Precision Scale Temp. Range 0x01 Heat 0,1 and 2 Celsius and Fahrenheit 8°C-28°C 0x0B Energy Heat 0,1 and 2 Celsius and Fahrenheit 8°C-28°C 7 Troubleshooting...
Need help?
Do you have a question about the Spirit Z-Wave Plus and is the answer not in the manual?
Questions and answers