2 Parameters
2.2 List of parameters
Note:
The identifier of a Technology Extension comprises a maximum of 8 characters plus separator.
TEC: Technology Extension
r4952
TEC DO-specific GUID total length / TEC DO GUID length
All objects
Can be changed: -
Data type: Unsigned16
P-Group: OEM range
Not for motor type: -
Min
0
Description:
Displays the total length of the GUIDs of the Technology Extensions installed on this drive object.
Dependency:
Refer to: r4950, r4951, r4955, p4956, r4957, r4958, r4959, r4960
Note:
The GUID of a Technology Extension comprises 16 characters plus 1 character major information plus 1 character,
minor information.
GUID: Globally Unique IDentifier
TEC: Technology Extension
r4955[0...n]
TEC DO-specific identifier / TEC DO ident
All objects
Can be changed: -
Data type: Unsigned8
P-Group: OEM range
Not for motor type: -
Min
-
Description:
Displays the identifier of the Technology Extensions installed on this drive object.
r4955[0...8]: Identifier of Technology Extension 1
r4955[9...17]: Identifier of Technology Extension 2, ...
Dependency:
Refer to: r4950, r4951, r4952, p4956, r4957, r4958, r4959, r4960
Notice:
If there is no Technology Extension, then it is not possible to access an index.
Note:
TEC: Technology Extension
p4956[0...n]
TEC DO-specific activation / TEC DO act
All objects
Can be changed: C1, T
Data type: Integer16
P-Group: OEM range
Not for motor type: -
Min
0
Description:
Setting to activate the Technology Extensions installed on this drive object.
r4956[0]: Activation of Technology Extension 1
r4956[1]: Activation of Technology Extension 2, ...
Value:
0:
1:
Dependency:
Refer to: r4950, r4951, r4952, r4955, r4957, r4958, r4959, r4960
Notice:
If there is no Technology Extension, then it is not possible to access an index.
Note:
TEC: Technology Extension
730
Technology Extension inactive
Technology Extension active
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
288
Calculated: -
Dyn. index: r4951
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: r4950
Unit group: -
Scaling: -
Max
1
List Manual (LH2), 07/2016, A5E03263479A
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0