p1678[0...n]
Speed actual value filter 5 denominator natural frequency / n_act_filt5 fn_den
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
0.5 [Hz]
Description:
Sets the denominator natural frequency for speed actual value filter 5 (PT2, general filter).
Dependency:
The speed actual value filter is activated via p1656.4 and parameterized via p1677 ... p1681.
p1679[0...n]
Speed actual value filter 5 denominator damping / n_act_filt 5 D_den
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
0.001
Description:
Sets the denominator damping for speed actual value filter 5.
Dependency:
The speed actual value filter is activated via p1656.4 and parameterized via p1677 ... p1681.
p1680[0...n]
Speed actual value filter 5 numerator natural frequency / n_act_filt5 fn_num
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
0.5 [Hz]
Description:
Sets the numerator natural frequency for speed actual value filter 5 (general filter).
Dependency:
The speed actual value filter is activated via p1656.4 and parameterized via p1677 ... p1681.
p1681[0...n]
Speed actual value filter 5 numerator damping / n_act_filt 5 D_num
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
0.000
Description:
Sets the numerator damping for speed actual value filter 5.
Dependency:
The speed actual value filter is activated via p1656.4 and parameterized via p1677 ... p1681.
p1699
Filter data acceptance / Filt data accept
VECTOR_G (n/M)
Can be changed: U, T
Data type: Integer16
P-Group: Closed-loop control
Not for motor type: REL
Min
0
Description:
Activates data acceptance for parameter changes for the filter.
p1699 = 0:
The new filter data are immediately accepted.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: CALC_MOD_CON
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
16000.0 [Hz]
Calculated: CALC_MOD_CON
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
10.000
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
16000.0 [Hz]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
10.000
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 4715
Unit selection: -
Expert list: 1
Factory setting
1999.0 [Hz]
Access level: 3
Func. diagram: 4715
Unit selection: -
Expert list: 1
Factory setting
0.700
Access level: 3
Func. diagram: 4715
Unit selection: -
Expert list: 1
Factory setting
1999.0 [Hz]
Access level: 3
Func. diagram: 4715
Unit selection: -
Expert list: 1
Factory setting
0.700
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
439