GE L90 Instruction Manual page 596

Ur series line current differential system
Hide thumbs Also See for L90:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 18 of 59)
ADDR
REGISTER NAME
4612
Charging Current Compensation
4613
Positive Sequence Reactance
4614
Zero Sequence Reactance
4615
Zero Sequence Current Removal
4616
Local Relay ID
B
4617
Terminal 1 ID
4618
Terminal 2 ID
4619
Channel Asymmetry Compensation
461A
Block GPS Time Reference
461B
Maximum Channel Asymmetry
461C
Round Trip Time
Breaker control (read/write settings)
4700
Breaker 1 function
4701
Breaker 1 name
4704
Breaker 1 mode
4705
Breaker 1 open
4706
Breaker 1 close
4707
Breaker 1 phase A / three-pole closed
4708
Breaker 1 phase B closed
4709
Breaker 1 phase C closed
470A
Breaker 1 external alarm
470B
Breaker 1 alarm delay
470D
Breaker 1 pushbutton control
470E
Breaker 1 manual close recall time
4710
Breaker 1 out of service
4711
Breaker 1 block open
4712
Breaker 1 block close
4713
Breaker 1 phase A / three-pole opened
4714
Breaker 1 phase B opened
4715
Breaker 1 phase C opened
4716
Breaker 1 operate time
4717
Breaker 1 events
4718
Reserved
4719
...Repeated for breaker 2
4732
...Repeated for breaker 3
474B
...Repeated for breaker 4
Synchrocheck (Read/Write Setting) (2 modules)
47A0
Synchrocheck 1 Function
47A1
Synchrocheck 1 V1 Source
47A2
Synchrocheck 1 V2 Source
47A3
Synchrocheck 1 Maximum Voltage Difference
47A5
Synchrocheck 1 Maximum Angle Difference
47A6
Synchrocheck 1 Maximum Frequency Difference
47A7
Synchrocheck 1 Dead Source Select
47A8
Synchrocheck 1 Dead V1 Maximum Voltage
47A9
Synchrocheck 1 Dead V2 Maximum Voltage
47AA
Synchrocheck 1 Live V1 Minimum Voltage
47AB
Synchrocheck 1 Live V2 Minimum Voltage
47AC
Synchrocheck 1 Target
47AD
Synchrocheck 1 Events
47AE
Synchrocheck 1 Block
47AF
Synchrocheck 1 Frequency Hysteresis
47B0
...Repeated for Synchrocheck 2
B-26
RANGE
0 to 1
0.1 to 65.535
0.1 to 65.535
0 to 1
0 to 255
0 to 255
0 to 255
0 to 65535
0 to 65535
0 to 10
0 to 10
0 to 1
---
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
---
0 to 1
0 to 5
0 to 5
0 to 400000
0 to 100
0 to 2
0 to 5
0 to 1.25
0 to 1.25
0 to 1.25
0 to 1.25
0 to 2
0 to 1
0 to 65535
0 to 0.1
L90 Line Current Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F102
kohms
0.001
F001
kohms
0.001
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F001
---
1
F300
---
1
F300
ms
0.1
F001
ms
0.1
F001
---
1
F102
---
---
F206
---
1
F157
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F003
---
1
F102
s
0.001
F003
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
---
1
F102
---
---
---
---
1
F102
---
1
F167
---
1
F167
V
1
F060
degrees
1
F001
Hz
0.01
F001
---
1
F176
pu
0.01
F001
pu
0.01
F001
pu
0.01
F001
pu
0.01
F001
---
1
F109
---
1
F102
---
1
F300
Hz
0.01
F001
DEFAULT
0 (Disabled)
100
100
0 (Disabled)
0
0
0
0
0
15
15
0 (Disabled)
"Bkr 1"
0 (3-Pole)
0
0
0
0
0
0
0
0 (Disabled)
0
0
0
0
0
0
0
70
0 (Disabled)
---
0 (Disabled)
0 (SRC 1)
1 (SRC 2)
10000
30
100
1 (LV1 and DV2)
30
30
70
70
0 (Self-reset)
0 (Disabled)
0
6
GE Multilin