6. Basic Operation

6.2 Height Alert Function

When the instrument system detects a shock, this
function informs the operator of it.
• When the instrument's installation status (height)
is sharply changed by the contact of the operator
or the like, this function stops auto leveling to
keep the operation accuracy and informs the
operator of the situation. The three lamps blink at
the same time as shown at the right.
• After 1 minute has passed since the auto leveling
function was activated and the laser beam was emitted, this function works.
• The height alert function does not work in the "Manual" mode.

How to reset

1
Turn off the power switch.
2
Check whether the instrument is installed correctly.
3
Turn on the power switch. Auto leveling starts again. After auto leveling is finished, the
laser beam is emitted.
4
Make sure that the laser beam is set at the correct height. Then, restart the operation.
Height Alert ON/OFF(Refer to "Height Alert ON/OFF" (p. 46)
28
Shock is given to the instrument.
Height Alert Display
(Flashing)

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RL-SV2S and is the answer not in the manual?

Questions and answers

Mohsen
March 8, 2025

Topcon RL SV2S I have a problem with a lot of errors Can't calibrate

User image 67cc425e8fa62
1 comments:
Mr. Anderson
March 8, 2025

Common calibration errors with the Topcon RL-SV2S include:

- E-65: Slope function error – Turn the instrument off and back on.
- E-70’s: Leveling incomplete – Turn the instrument off and back on.

If errors persist, contact Topcon or your dealer.