3. First Step
(6) Select the "No.1 USB" and click the <Connect> button.
(7) After development PC and the Controller connection is completed, "Connected"
is displayed in the [Connection status:]. Make sure that "Connected" is
displayed and click the <Close> button to close the [PC to Controller
Communications] dialog.
Connection of the development PC and the Controller is completed. Now robot
system can be used from EPSON RC+ 7.0.
3.2.4 Backup the initial condition of the Controller
Backup the Controller data configured before shipment.
Follow these steps to backup the project and system configuration:
80
(1) From the [Project] menu, select [Copy].
(2) Change the [Destination Drive] to an arbitrary drive.
(3) Click <OK>. The project will be copied to the external media.
(4) From the [Tools] menu, select [Controller].
(5) Click on the <Backup Controller> button.
(6) Select the arbitrary drive.
(7) Click <OK>. The system configuration will be backed up on the
external media.
Safety and Installation (RC90 / EPSON RC+ 7.0) Rev.5