Controller - Epson RC90 Safety And Installation

Robot system
Hide thumbs Also See for RC90:
Table of Contents

Advertisement

5. General Maintenance

5.1.2 Controller

Part
Content
Code
Quantity
Maintenance
interval
Possible
malfunction if
maintenance
is not performed
Duration
(reference)
Reference:
Maintenance
Expected
product life
98
Fan filter
Cleaning
-
-
More than once
a month is
recommended
The temperature
inside the
Controller may
get too high and
the robot system
may not operate
properly.
The error may
occur due to
reduction of the
fun rotation.
5 minutes
7.1
Fan Filter
-
Safety and Installation (RC90 / EPSON RC+ 7.0) Rev.5
Replacement
R13B60511
1
When the filter
gets deteriorated
The robot system
may not operate
properly due to
dust or the like.
5 minutes
7.1
Fan Filter
-
Fan
Replacement
R13B060510
R13B060003
1
1
Every 5 years,
When the error
or when the
515 occurs, or
error 511 occurs
when the
abnormal noise
occurs
The error 9015
The error 9011
occurs and the
occurs and the
robot system
robot system
may stop.
may stop.
20 minutes
15 minutes
7.2
7.3
Fan
Battery
-
30,000 hours
Battery
Replacement

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ls6Ls3Ls20

Table of Contents