CHAPTER 7.
This chapter describes how to connect stations and additional equipment such as ana-
log/digital phones, door phones and door locks to the OfficeServ system.
7.1 Connecting Stations
7.1.1 Caution When Connecting Stations
Do not connect stations in extreme weather conditions such as storms and lightning.
Do not connect stations in areas of high humidity.
Comply with the station user guide, this guide and other relevant guides when recon-
necting stations or changing connections.
Connect stations with a pair of #24 AWG or #26 AWG cables.
The maximum distances between stations and the OfficeServ system are shown in Table
7.1.
Digital Phone
Analogue Phone
Door Phone
AOM
WBS24
© Samsung Business Communications
Connecting Stations and
Additional Equipment
Table 7.1 Maximum Distance between Stations and the System
Station
OfficeServ 7400 Installation Guide
Maximum Distance
400 m (for AWG #24)
1000 m (for AWG #24)
400 m (for AWG #24)
400 m (for AWG #24)
600 m (for 0.64 twisted cable)
400 m (for 0.40 twisted cable)
7-1