6. Troubleshooting
SC No.
SC540-00
Fusing Sleeve (Center) Error (SC54*-**)
SC No.
SC541-01
822
Type
Error Name/Error Condition/Major Cause/Solution
D
Fusing Motor: Lock
Motor status is observed at 0.1 sec intervals during motor ON, and the
unlock status is detected at least 20 times.
• Motor defective
• Connector disconnected
• Harness broken
• IOB defective
• Unit torque increased
• Replace the fusing motor.
• Reconnect the connector.
• Replace the harness.
• Replace the paper transport IOB.
Type
Error Name/Error Condition/Major Cause/Solution
A
Thermopile (Center) Disconnection
Below -50 degrees C (or below CB) is detected for 0.1 sec continuously.
• Thermopile disconnection
• Connector disconnected
• Harness disconnection between the fusing unit and the BCU
• BCU defective
1. Reconnect the connectors (main machine side, BCU side).
2. Replace the thermopile (center).
3. Replace the harness between the fusing unit and the BCU.
4. Replace the BCU.