Panasonic KX-NS1000 Installation Manual page 184

Pure ip-pbx
Hide thumbs Also See for KX-NS1000:
Table of Contents

Advertisement

5.3 Starting Web Maintenance Console
added to the base KX-NS1000 system data, and then converted for use in a Slave unit. The conversion results
are used as the system data of a KX-NS1000 (Master unit) that controls one or more Slave units.
1.
Connect a PC to a KX-TDE series, KX-NCP series PBX and then start the Unified Maintenance Console.
For details about connecting a PC to a PBX or for details about the Unified Maintenance Console, refer to
the appropriate documentation.
2.
In the Unified Maintenance Console, save the PBX's system data file (DxSYS
For details about saving the system data file to the PC, refer to the appropriate documentation.
3.
Start Web Maintenance Console for the KX-NS1000 in Off-line mode.
4.
In the Program Launcher, click Database Converter.
5.
In Select Converter Type, click Slave data converter.
6.
In TDE/NCP System Data, select the appropriate option according to whether a legacy gateway is
connected.
7.
In Select Original File Name, select the system file (DxSYS) you saved in step 2 as the file to convert.
8.
In NS1000 System Data to Add Site, select the system file (DCSYS) for the Master unit as the file to
convert.
9.
In Convert Site List, the site ID and the site information is displayed.
10.
Click Next. In Convert Image, an image of converting the file to the KX-NS1000 is displayed on the screen.
11.
Click Next. In Convert Option, you can select whether each item displayed on screen will be converted.
12.
Specify the following Slave unit parameters as necessary:
CO & Incoming Settings–DDI/DID Table
Numbering Plan–Main–Other PBX Extension
Maintenance–SNMP–System Setting–MIB–SysName
13.
Click Next. In Setup Slave Unit, specify the necessary information for the Slave units. Operation and
programming items are same as the Add Site Wizard. For more information, refer to "5.5 Programming a
One-look Network".
14.
Click Next. If you are converting a shelf of a KX-TDE600 for two sites, after you finish configuring the first
site, return to step 13 and configure the second site.
After you have finished, continue to the next step. For all other PBXs, continue to the next step.
15.
After conversion is complete, you can click Save on the Result of Converting screen and save the results
file (ConvertReport.txt) to your PC.
16.
On the Save Converted File of System Data screen, save the created DCSYS file.
17.
To add an additional Slave unit with another DxSYS file, click Continue and return to step 7. If you have
finished adding Slave units, click Finish and continue to the next step.
18.
In Select Next Step, select the next step and then click OK. Conversion is complete.
19.
Start Web Maintenance Console, and click Open -Offline Mode in the Program Launcher.
20.
Select the created DCSYS file, and configure any additional required parameters.
For details about the parameters, refer to the PC Programming Manual.
21.
Start the KX-NS1000, and then transfer the system data file (DCSYS) to the PBX.
For details about transferring the file, refer to "1.2.2 PC Programming Using Off-line Mode— Uploading
Programmed Settings to the PBX" in the PC Programming Manual.
*1
"DxSYS" refers to the following:
KX-NCP500/KX-NCP1000: DBSYS
KX-TDE100/KX-TDE200: DMSYS
KX-TDE600: DGSYS
*2
The software version for KX-TDE series or KX-NCP series PBXs must meet the latest version requirements shown in the Data
Converter tool. If the requirements are not met, you must use the Unified Maintenance Console to upgrade the version to the one
shown in the table below, and then save the DxSYS file.
Notice
Activation keys are not brought over during data conversion. You must supply the necessary activation
keys for the KX-NS1000 separately.
184
Installation Manual
) to the PC
.
*1
*2
Document Version 2016-03

Hide quick links:

Advertisement

Table of Contents
loading