exup.fm
Expanding and Upgrading HiPath 3000
Expanding HiPath 3000
9.2.4.2

Components

Expansion cabinet rack (ECR): S30777-U711-E901
The scope of delivery includes:
A mounting set for installing the ECR in a 19-inch cabinet: C39165-A7027-D1
A mounting clamp: D72571-A80-S3
A toothed lock washer: D6797-A43-S657
Mounting set for ECR wall installation or ECR table setup: C39165-A7027-D2
EPSU2-R: S30122-K7221-X900
A cable for making the ECR – HiPath 3500 or HiPath 3300 electrical connection is included
in the delivery: C39195-Z7001-C14
4 batteries, 12 V/7 Ah: 4 x V39113-W5123-E891
Connection cable, ECR (batteries) – HiPath 3700 (UPSM + power failure signaling (lamp-
wire connector): a relay connected in series can be used for signaling purposes, for exam-
ple.): C39195-A7002-B11
Connection cable, ECR – HiPath 3500 or HiPath 3300: S30267-Z361-A10
Caution
7
Both of the above-mentioned connection cables are system-specific.
C39195-A7002-B11 is exclusively designed for HiPath 3700.
S30267-Z361-A10 is exclusively designed for HiPath 3500 and HiPath 3300.
Failure to observe the above may damage the power supply unit.
9.2.4.3

Installation Options

Use the power cable to ground the ECR. Fixed, separate grounding is not required.
>
The expansion cabinet rack ECR can be
installed in a 19-inch cabinet (see Section 4.4.4.5).
mounted on a wall (see Section 4.4.4.4).
set up on a table using four adhesive mounting feet.
9-12
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual