3.2 Electrical Wiring

The following figure shows overall terminal arrangement of the NICE3000
Figure 3-10 Overall terminal arrangement of the NICE3000

3.2.1 Standard System Wiring Diagram

Figure 3-11 Standard wiring diagram of the NICE3000
new
PRG
UP
SET
CN1
NICE3000
integrated elevator
J12
controller
CN9
J5
J1
CN7
CN2
CN3
new
control system
3 Mechanical and Electrical Installation
new
.
CN5
J9
J10
CN12
new
J6
J7
CN4
3
- 35 -

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the nice3000 and is the answer not in the manual?

Questions and answers

نعيم درجال الكناني
March 3, 2025

عندي لوحة يظهر في الشاشة رقم 8 فقط في وسط الشاشة ولايتحكم في أي شئ

User image 67c6282153cf3
Emmanuel
April 12, 2025

New Fuji elevator with monarch drive The door operator open signal light doesn't come on

User image 67f9bb058a585
1 comments:
Mr. Anderson
April 12, 2025

The door operator open signal light may not come on for the Monarch NICE3000 drive in the new Fuji elevator due to one or more of the following reasons:

1. Opposite Door Function Mode: If the system is in opposite door control mode, the door open signal function is only enabled in mode 2 (hall call independent, opposite-door manual control). If the system is not configured correctly for this mode, the signal may not activate.

2. Input Configuration (JP16/IP16): If JP16 or IP16 inputs are not correctly set, the system may not recognize the correct door (front or back) to open, preventing the open signal from activating.

3. Door Lock Signal Issue: If the door lock signal is invalid or the door and hall door are in different states, the system may block the door open signal.

4. Elevator Lock Signal Active: If the elevator lock signal is active, the elevator will not respond to calls, and no door open signal will be generated.

5. Fault Conditions: Certain faults like motor overheat (Err39) or communication failure (E57) can prevent normal operation, including door opening.

6. Door Open Limit Signal Not Detected: If the door open limit signal is not properly detected (E55), the system may not allow the door to open.

Check these conditions and signals to determine the cause.

This answer is automatically generated

Shahzaib
February 10, 2025

Error 47 subcode 201