82
Symbols
I
max
Normal use (10% overload capability)
I
2N
P
N
Heavy-duty use (50% overload capability)
I
2hd
P
hd
Note: The ratings apply at an ambient temperature of 40 °C (104 °F). At lower temperatures the ratings
are higher.
Technical Data
maximum output current. Available for 10 s at start, otherwise as long as allowed by drive
temperature.
continuous rms current. 10% overload is typically allowed for one minute every 5 minutes.
typical motor power. The power ratings apply to most 4-pole NEMA rated motors
continuous rms current. 50% overload is typically allowed for one minute every 5 minutes.
typical motor power. The power ratings apply to most 4-pole NEMA rated motors