Panasonic kx-ns0154la Installation Manual page 29

Dect 4-channel ip cell station unit
Table of Contents

Advertisement

PROBLEM
Noise is frequent while
using the PS.
Conversations disconnect
while using the PS.
There is noise during a
phone call.
Call handover is not
working.
"NO SERVICE" is displayed
on the PS's screen.
When traditional CSs are
assigned as Master CSs:
IP-CSs reset frequently.
KX-TCA175/KX-TCA275
PSs do not operate
properly.
PS stays out of service
when the CS status is
changed from Out of
Service to In Service.
IP-CSs are installed at a
remote site after installing
CSs at a local site, but the
IP-CSs do not operate.
After uninstalling some
CSs, other CSs do not
operate.
PROBABLE CAUSE
PS is out of CS coverage
area.
In LAN synchronization case:
LAN synchronization to
Master CS has failed.
In air synchronization case:
The clock signal source CS
is out of range for air
synchronization.
In air synchronization case:
Air synchronization's
Master CS1 and Master
CS2 has failed and each
CS is generating its own
clock signal.
Metallic materials in the
surrounding structure are
interfering with the signal
received by the PS.
In air synchronization case:
The software version of the
traditional CSs is old.
It may take about 20 s for
the CS to start up after the
status has been changed
to In Service.
In air synchronization case:
IP-CSs are not properly
synchronized with any CS.
In air synchronization case:
Master CS is uninstalled.
SOLUTION
Locate the CS properly (refer to
"3.3 Site Survey").
Check the network configuration (refer
to "5.3 Recommended Network
Configuration").
Diagnose the network configuration
with IP Terminal Maintenance Console
(refer to "5.12 IP Terminal
Maintenance Console").
Locate the CS properly (refer to
"3.3 Site Survey").
Confirm the error log from Utility—Error
Log—Minor using the Maintenance
Console. If "369 IP-CS Handover
error" is displayed for the error log,
restart Master CS1 and Master CS2.
Install an additional CS where the
signal interference is worst.
Update the traditional CSs to version
5.000 or later.
Wait until the CS starts up.
When using only one IP-CS at a remote
site, assign the IP-CS as Master CS1.
When using multiple IP-CSs at a
remote site, establish air
synchronization between IP-CSs.
Assign a Master CS again for air
synchronization (refer to "Assigning the
Synchronizing CSs").
4 Troubleshooting
Installation Guide
29

Advertisement

Table of Contents
loading

Table of Contents