ABB Freelance 2000 Manual page 126

Operator station configuration
Table of Contents

Advertisement

Section D
Examples of user defined data formats:
Data type
REAL
INT, UINT, DINT, UDINT
BYTE, WORD, DWORD
TIME
DT
STRING types
Control characters for use with strings:
.
Number of displayed characters.
S:
Position of the first character to be displayed.
Character 1 occupies position 0.
Z:
Line to be displayed, for all lines enter 0.
I:
Display of control characters and margin delimiters;
Options y or n.
T:
Interpret tab signs, options y or n.
Control characters:
$R
Carriage Return (CR),
$N
Line Feed (LF),
$L
Carriage Return and Line Feed ($R$N),
$T
Tab,
$ff
Hex-coded ASCII character (e.g. '$41' for 'A'),
$'
Apostrophe (')
$$
Dollar sign ($).
Gross Automation, 1725 South Johnson Road, New Berlin, WI 53146, www.ssacsales.com, 800-349-5827
D-52
Format
[+|-| ]f.ff...{E[+|-]ee}
[+|-]fff...
0f
see fixed data format
see fixed data format
s:L{,S}:Z:I:T
Graphic Display
Example
3.141E+00, 3.0, -4.2, +6.2E-05
35, 4000, +500
07
High, Low
Default: all
Default: 0
Default: 0
Default: y
Default: n

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents