SETTINGS AND PROCEDURES BEFORE
OPERATION
Number
4)
Start-up part terminal block
5)
Safety output part terminal block
Extension communication
6)
station number setting switch
Extension communication
7)
terminating resistor setting
switch
8)
Start-up mode setting switch
9)
Safety part extension connector IN, OUT
10)
Serial number display
Table 5.3 Part names (2/2)
Name
XS
XS0, XS1: Start-up/off, check terminal
Z00, Z01: Safety relay output terminal
Z10, Z11: Safety relay output terminal
Z20, Z21: Safety relay output terminal
A switch for setting the station number of extension communication
LOCAL ST No.
Switch 1: Reserved
Switch 2
LT
ON: Terminating resistor is attached.
OFF: Terminating resistor is not attached.
A switch for setting start-up input mode
"A" side: Auto mode
"M" side: Manual mode
A connector for connecting an extension module
IN: A connector for connecting a module to the previous module with safety
part extension cable at extension
OUT: A connector for connecting a module to the next module with safety part
extension cable at extension
A serial number same as the one shown on the rating plate
Description
Setting switch status (LOCAL ST No.)
Setting
8
4
1
OFF
OFF
2
OFF
OFF
3
OFF
OFF
Set a station number within the range from 1 to 3.
Setting 4 or later may cause an error.
5.3 Extension Safety Relay Module
5.3.3 Part names and settings
2
1
OFF
ON
ON
OFF
ON
ON
5
- 16
1
2
3
4
5
6