5
SETTINGS AND PROCEDURES BEFORE
OPERATION
5.1.3

Part names and settings

This section explains each part name of the Q series safety relay module.
9)
Number
1)
Indicator LED
Figure 5.2 Q series safety relay module
Table 5.1 Part names (1/2)
Name
Indicates status of module power supply.
PW
ON: Module power supply is supplied.
OFF: Module power supply is cut off or electric fuse functions.
Indicates a failure in the monitor function of a module or an error in
communications with the extension module.
ERR.
ON: An error occurred in communications with the extension safety relay
module.
OFF: Normal
Indicates status of safety output.
Z
ON: Safety output is generated (both K0 and K1 are ON).
OFF: Safety output is not generated.
X0
Indicates status of safety input (X0, X1).
ON: Safety input is generated.
X1
OFF: Safety input is not generated.
Indicates status of safety power supply.
S PW
ON: Safety power supply is supplied.
OFF: Safety power supply is cut off or electric fuse functions.
Indicates operating status of the internal safety relay K0 (coil status of K0).
K0
ON: Operating status of the internal safety relay K0 is ON.
OFF: Operating status of the internal safety relay K0 is OFF.
Indicates operating status of the internal safety relay K1 (coil status of K1).
K1
ON: Operating status of the internal safety relay K1 is ON.
OFF: Operating status of the internal safety relay K1 is OFF.
1)
8)
2)
3)
Description
5.1 Q Series Safety Relay Module
5.1.3 Part names and settings
1
2
8)
6)
7)
3
4)
5)
4
5
6
5
- 4