KB-3425LS/K/W
KB-4425LS/K/W
Pin No.
Signal
47
P47
48
CS2
49
P45
50
P44
5
P43
52
P42
53
P4
54
P40
55
P37
56
P36
57
P35
58
P34
59 - 6
A - A9
62
VCC2
63
A8
64
VSS
65 - 70
A7 - A2
7
A
72
A0
73
P7
74
P6
75
P5
76
P4
I/O
OUT
Reset signal is outout to the LCD.
OUT
Chip select signal is outout to the LCD.
OUT
Turminal not used.
OUT
Turminal not used.
OUT
Signal to turn on the indicator for the Cook Top Warmer is output to the LED (LD0).
Door lock motor driving signal.
OUT
To turn on and off shut-off relay(RY8).
"H"level during door lock motor driving
"L" level otherwise
OUT
Power source to drive the Microwave drawer door open-close motor is output.
IN
Turminal not used.
Convection heater relay driving signal.
OUT
To turn on and off relay(RYC).
"H" level: During convection heater relay ON.
"L" level: During convection heater relay OFF.
Bottom heater relay driving signal.
OUT
To turn on and off relay(RYB).
"H" level: During bottom heater relay ON.
"L" level: During bottom heater relay OFF.
Cook top warmer driving signal.
OUT
To turn on and off relay(RY0).
"H" level: During cook top warmer ON.
"L" level: During cook top warmer OFF.
OUT
Oven convection motor driving signal.
To turn on and off relay(RY9).
"H" level: During convection motor ON.
"L" level: During convection motor OFF.
OUT
Turminal not used.
IN
Power source voltage: +3.3V.
The power source voltage to drive the LSI (IC-) is input to VCC2 terminal.
OUT
Turminal not used.
IN
Power source voltage: 0V (GND).
VS voltage of power source circuit input. Connected to GND
OUT
Turminal not used.
OUT
Register select signal is input to the LCD.
OUT
Turminal not used.
OUT
Signal to sound buzzer.
A: Key touch sound (short beep).
B: Completion sound (melody or long beep).
Door lock motor (Oven) driving signal.
OUT
To turn on and off relay(RY8).
"H" level: During door lock motor ON.
"L" level: During door lock motor OFF.
Oven lamp (Oven) driving signal.
OUT
To turn on and off relay(RY7).
"H" level: During oven lamp ON.
"L" level: During oven lamp OFF.
Fan motor (Oven) driving signal.
OUT
To turn on and off relay(RY6).
"H" level: During fan motor ON.
Description
32
ON
H: +5V
During
door lock
OFF
motor driving
L: GND
ON
H: +5V
L: GND
OFF
ON
H: +5V
L: GND
OFF
ON
H: +5V
L: GND
OFF
ON
H: +5V
L: GND
OFF
ON
H: +5V
L: GND
OFF
ON
H: +5V
L: GND
OFF
ON
H: +5V
L: GND
OFF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kb-4425lsKb-4425lkKb-3425lwKb-4425lwKb-3425lk

Table of Contents