PROGRAMMING NOTES

Compatibility: This document applies to systems with microprocessor version number WA3001-9.1 or higher.

PROGRAM MODE OVERVIEW

IMPORTANT: The Real-Time Clock must be set before the end of the installation.
To Enter Programming Mode:
Local programming requires the use of a Custom English touchpad connected to the touchpad terminals on the control.
1. POWER UP, then depress [
2. OR, key: Installer Code (default = 6321) then 8-0-0.
(if
,
98 was used to exit previously, method 1 above must be used to enter the program mode again)
PROGRAMMING COMMANDS
NOTE: Keystrokes are made sequentially unless otherwise instructed (ex. "[#] + 64" means press [#] then 6 then 4)
Task
Go to a Data Field
Entering Data
Review a Data Field
Deleting an Entry
Initialize Download ID
Reset Factory Defaults
Zone Programming
Function Key Programming Press ∗ ∗ ∗ ∗ 57. Unlabeled touchpad keys (known as ABCD keys) for special functions
Zone Programming
(Expert Mode)
Output Device Mapping
Output Programming
Zone List Programming
Alpha Programming
IP/GSM Programming
Exit Program Mode with
installer code lockout
Exit Program Mode
Scheduling Mode
Site-Initiated Download
AVS QUICK PROGRAMMING COMMANDS (for AAV sessions using the AVS system)
For controls with firmware revision level 7.0 or higher, these commands automatically configure the control for AVS operation.
• installer code + [#] + [0] + 3: enable AVS operation
• installer code + [#] + [0] + 4: enable AVS operation and enable panel sounds on the AVST speaker
• installer code + [#] + [0] + 5: remove all programming options set by [#] + [0] + 3 quick command
• installer code + [#] + [0] + 6: remove all programming options set by [#] + [0] + 4 quick command
Refer to the AVS SYSTEM ENABLE and QUICK PROGRAMMING COMMANDS section for details on the specific options
that are set with each command, depending on the control used.
To select the AAV session communication path (phone line/communication device), see field ∗55 Dynamic Signaling Priority.
To enable AAV operation, use ∗91 Options field (option 4).
SPECIAL MESSAGES
• OC = OPEN CIRCUIT (no communication between Touchpad and Control).
• EE or ENTRY ERROR = ERROR (invalid field number entered; re-enter valid field number).
• After powering up, AC, dI (disabled) or "Busy Standby vx.x (firmware revision) Dl will be displayed after approximately 4
seconds. This will revert to a "Ready" message in approximately 1 minute, which allows PIRS, etc. to stabilize. You can
bypass this delay by pressing [#] + [0].
NOTE for CANADIAN PANELS: Power up time is 2 minutes, and Contact ID report code 305 System Reset is sent if the
[#] + [0] command is not performed before the 2 minutes expires.
• If E4 or E8 appears, more zones than the expansion units can handle have been programmed. The display will clear after
you correct the programming.
] and [#] both at once, within 50 seconds of powering up.
,
Command/Explanation
Press [∗ ∗ ∗ ∗ ] + [Field Number], followed by the required entry.
When the desired field number appears, simply make the required entry. When the last entry
for a field is entered, the touchpad beeps three times and automatically displays the next data
field in sequence. If the number of digits that you need to enter in a data field is less than the
maximum digits available (for example, the phone number fields *41, *42), enter the desired
data, then press [∗ ] to end the entry. The next data field number is displayed.
Press [#] + [Field Number].
Data will be displayed for that field number. No changes will be accepted in this mode.
Press [∗ ∗ ∗ ∗ ] + [Field Number] + [∗ ∗ ∗ ∗ ]. (Applies only to fields ∗40 thru *45, *94, and pager fields)
Press ∗ ∗ ∗ ∗ 96. Initializes download ID and subscriber account number.
Press ∗ ∗ ∗ ∗ 97. Sets all data fields to original factory default values.
Press ∗ ∗ ∗ ∗ 56. Zone characteristics, report codes, alpha descriptors, and serial numbers for 5800
RF transmitters.
Press ∗ ∗ ∗ ∗ 58. Same options as *56 mode, but with fewer prompts. Intended for those familiar
with this type of programming, otherwise *56 mode is recommended.
Press ∗ ∗ ∗ ∗ 79. Assign module addresses and map individual relays/powerline carrier devices
Press ∗ ∗ ∗ ∗ 80. 4229 or 4204 Relay modules, powerline carrier devices, or on-board triggers
Press ∗ ∗ ∗ ∗ 81. Zone Lists for relay/powerline carrier activation, chime zones, pager zones, etc.
Press ∗ ∗ ∗ ∗ 82. Zone alpha descriptors
Press ∗ ∗ ∗ ∗ 29. For programming the IP/GSM options.
Press ∗ ∗ ∗ ∗ 98. Exits programming mode and prevents re-entry by: Installer Code + 800.
To reenter programming mode, the system must be powered down, then powered up. Then
use method A above.
Press ∗ ∗ ∗ ∗ 99. Exits program mode and allows re-entry by: Installer Code + 800 or method A
above.
Enter code + [#] + 64. Create schedules to automate various system functions.
Installer code + [#] + 1 (perform while system is disarmed and in normal mode)
– 3 –