ISSUE 3.0

1.5.1 Grounding the KSU

Ensure all Main and Expansion KSU(s) are powered off and unplug the AC
cord.
In each KSU, connect the ETH lug to the verified grounding point using a minimum cable size of
14AWG (Φ2.0 mm) wire.
Screw
ETH Lug
• The grounding cable is supplier-provided.(not attached to the system)
1.
Loosen the screw.
2.
Insert a grounding wire (user supplied).
3.
Tighten the screw.
4.
Connect the grounding wire to earth ground.
Proper grounding is very important to protect the system from external
noise and to reduce the risk of electrocution in the event of a lightning
strike.

1.5.2 AC Power Requirement

A dedicated 100V-120V/220V/230V/240V 50/60Hz circuit located within two meters of the KSU is
required. A separate dedicated AC outlet is necessary for each KSU.
Double Pole/Neutral Fusing
(Power supply fuses are located at both the L and N side.)
110 VAC
Power Require-
110 VAC@15 A
ments
Power Con-
Main KSU = 144 VA
sumption
4 KSU Total = 576 VA
Input Voltage
(Rated Voltage)
Frequency
Phase and Wire
Grounding Re-
quirement
Hardware Manual
To Earth

Figure 2-18 ETH Lug

Table 2-5 Power Requirement

220 VAC
220 VAC@15 A
Main KSU = 172 VA
4 KSU Total = 688 VA
90 VAC to 264 VAC (100VAC/120VAC/220VAC/230VAC/240VAC)
47 Hz - 63 Hz (Rated Frequency:50/60 Hz)
Single Phase, 2 Line + PE Type
No.14 AWG Copper Wire
230 VAC
230 VAC@15 A
Main KSU = 175 VA
Main KSU = 175 VA
4 KSU Total = 700 VA
4 KSU Total = 700 VA
SL1000
240 VAC
240 VAC@15 A
2-13