Bleeding Air From The Injectors - Toro 30410 Operator's Manual

Traction unit
Hide thumbs Also See for 30410:
Table of Contents

Advertisement

2. Loosen the drain plug on the bottom of the filter
canister.
1. Water separator filter canister
3. Clean the area where the filter canister mounts.
4. Remove the filter canister and clean the mounting
surface.
5. Lubricate the gasket on the filter canister with clean
oil.
6. Install the filter canister by hand until the gasket
contacts mounting surface, then rotate it an
additional 1/2 turn.
7. Tighten the drain plug on the bottom of the filter
canister.

Bleeding Air from the Injectors

1. Loosen the pipe connection to the Number 1
injector nozzle and holder assembly at the injection
pump (Figure 52).
1. Number 1 injector nozzle
2. Move the throttle to the Fast position.
3. Turn the key in the ignition switch to the Start
position and watch the fuel flow around the
connector. Turn the key to the Off position when
solid flow is observed.
Figure 51
Figure 52
4. Tighten the pipe connector securely.
5. Repeat the procedure on the remaining nozzles.
38

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Groundsmaster 4000-d30410te