Operating The Sprayer - Toro 41165 Operator's Manual

Turf sprayer
Hide thumbs Also See for 41165:
Table of Contents

Advertisement

4. Set the dial on the Spray Pro monitor to Application
Rate.
5. Place the range selector in the Neutral position.
6. Press the accelerator to the floor and set the neutral
engine speed control switch to the On position.
7. Set the pump switch to the On position to start the
pump.
8. Set all three boom switches and the master boom switch
to the On position.
9. Use the application rate switch to adjust the pressure as
read on the pressure gauge until it is in the range for the
nozzles you installed on the booms (typically 50 psi).
10. Record the reading on the pressure gauge.
11. Turn off one of the booms using the appropriate boom
switch.
12. Adjust the boom bypass valve (Fig. 28) under the boom
control valve for the boom you turned off until the
pressure reading on the gauge is the same as it was in
step 9.
Figure 28
1. Boomy bypass valves
13. Turn the boom on.
14. Repeat steps 11 through 13 for the other booms.
15. Drive the sprayer at the desired speed while spraying
and turn each boom off individually. The pressure on
the gauge should not change much.

Operating the Sprayer

To operate the sprayer you first fill the spray tank, then
apply the solution to the work area, and finally clean the
tank. It is important that you complete all three of these
steps in succession to avoid damaging the sprayer. For
example, do not mix and add chemicals in the spray tank at
night and then spray in the morning. This would lead to
separation of the chemicals and possible damage to the
sprayer components.
1
Caution
Chemicals are hazardous and can cause personal
injury.
• Read the directions on the chemical labels
before handling the chemicals and follow all
manufacturer recommendations and
precautions.
• Keep chemicals away from your skin. Should
contact occur, wash the affected area thoroughly
with soap and clean water.
• Wear goggles and any other protective
equipment recommended by the chemical
manufacturer.
Filling the Spray Tank
Important
Ensure that the chemicals you will be using
are compatible for use with Viton (see the manufacturer's
label; it should indicate if it is not compatible). Using a
chemical that is not compatible with Viton will degrade the
o-rings in the sprayer, causing leaks.
1. Stop the sprayer on a level surface, move the range
selector to the Neutral position, stop the engine, and set
the parking brake.
2. Determine the amount of water needed to mix the
amount of chemical you need as prescribed by the
chemical manufacturer.
3. Open the lid on the spray tank.
4. Add 3/4 of the required water to the spray tank using
the anti-siphon fill receptacle.
Important
Always use fresh clean water in the spray
tank. Do not pour concentrate into an empty tank.
5. Start the engine, press the accelerator pedal to the floor,
and set the neutral engine speed control to the On
position.
6. Set the pump switch to the On position.
7. Turn the agitation control valve to the 9 o'clock
position to start agitation in the tank.
8. Add the proper amount of chemical concentrate to the
tank, as directed by the chemical manufacturer.
Important
If you are using a wetable powder, mix the
powder with a a small amount of water to form a slurry
before adding it to the tank
9. Add the remaining water to the tank.
26

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multi-pro 1250

Table of Contents