Device Type - Panasonic KX-TDA100 Pc Programming Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA100:
Table of Contents

Advertisement

Device Type

Selects the type of connected output device (for output ports only).
Value Range
Relay, Ringer
Maintenance Console Location
2.8.41 [1-1] Slot—Card Property - OPB3 (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
1.17.10 External Relay Control
Input Signal Decision Time
Specifies the minimum duration of continuous input from the triggered sensor before the PBX
recognises the input and makes a sensor call.
Value Range
32 × n (n=2–255) ms
Maintenance Console Location
2.8.41 [1-1] Slot—Card Property - OPB3 (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
1.17.9 External Sensor
Input Signal Detection Reopening Time
Specifies the length of time after the sensor has been triggered during which any further input from
the sensor will be ignored.
Value Range
10 × n (n=1–255) s
Maintenance Console Location
2.8.41 [1-1] Slot—Card Property - OPB3 (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
2.8 [1] Configuration
PC Programming Manual
325

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tda30Kx-tda200Kx-tda600

Table of Contents