2.8 [1] Configuration
Feature Guide References
None
E&M Signalling Type
Selects the control bit of an E & M signal.
Value Range
Type-1:A bit=0, Type-2:A bit=1, Type-3:B bit=0, Type-4:B bit=1, Type-5:A bit=1,B bit=1
Maintenance Console Location
2.8.22 [1-1] Slot—Card Property - E1 type—Line Signal Setting
Programming Manual References
None
Feature Guide References
None
Wink Signal Width
Specifies the length of a wink signal.
Value Range
32 × n (n=4–9) ms
Maintenance Console Location
2.8.22 [1-1] Slot—Card Property - E1 type—Line Signal Setting
Programming Manual References
None
Feature Guide References
None
E&M-P Pulse Length—Seizure
Specifies the length of a seizure signal.
Value Range
150 ms, 600 ms
Maintenance Console Location
2.8.22 [1-1] Slot—Card Property - E1 type—Line Signal Setting
Programming Manual References
None