'Dos' and 'Don'ts'
SLENDERTONE
Abdominal Training Systems are suitable for
S LEND ERTO NE
use by all healthy adults. However, as with other forms of
exercise, some care is needed when using them, so
always follow the points below and read the support pack
before use. Some of the points below are gender specific.
Please do not use if:
• You have an electronic implant (e.g. cardiac pacemaker)
or suffer from any other heart problem.
• You are pregnant.
• You suffer from cancer, epilepsy or are under medical
supervision for cognitive dysfunction.
• The unit is in close proximity (e.g. 1m) to shortwave or
microwave therapy equipment.
• You are connected to high-frequency surgical
equipment.
• Wearing the device necessitates placement over areas at
which drugs/medicines are administered by injection
(short term or long term) e.g. hormone treatment.
Please wait before using your slendertone Abdominal
Training System until:
• At least six weeks after the birth of your baby (you must
consult your doctor first).
• One month after an IUD contraceptive device (e.g. coil)
has been fitted.
• At least three months after having a Caesarean (you
must consult your doctor first).
• The heavy days of your period have finished.
Please get your doctor's or physio's permission
before using this product if:
• You wish to use a
belt and have a bad back.
SLENDERTONE
You should also ensure the intensity is kept low.
• You have any serious illness or injury not mentioned in
this guide.
• You have recently had an operation.
• You take insulin for diabetes.
• You want to use it on a young child.
• You suffer from muscle or joint problems.
• Using the device as part of a rehabilitation programme.
When applying the pads and belt, always remember to:
• Place the pads and belt ONLY on the abdomen as
indicated in this manual.
• Avoid placing the pads or belt on the front or sides of
the neck, across or through the heart (i.e. one pad on
the front of the chest and one on the back), in the
genital region or on the head. (Other
SLENDERTONE
are available for other areas of the body – details are
available from your stockist)
• Avoid any recent scars, broken or inflamed skin, areas
of infection or susceptibility to acne, thrombosis or
other vascular problems (e.g. varicose veins), or any
parts of the body where feeling is limited.
10
• Avoid areas of injury or restricted movement
(e.g. fractures or sprains).
• Avoid placing the pads directly over metal implants.
They may be placed on the nearest muscle.
Possible adverse reactions
• A small number of isolated skin reactions have been
reported by people using muscle stimulation devices,
including allergies, a prolonged reddening of the skin
and acne.
To reposition pads during a session
• Always pause the programme currently running,
unfasten the belt and then refasten it behind your back
once the pads' position has been adjusted.
After strenuous exercise or exertion
• Always use a lower intensity to avoid muscle fatigue.
Contact slendertone or an authorised distributor if:
• Your unit is not working correctly. Do not use in the
meantime.
• You experience any irritation, skin reaction,
hypersensitivity or other adverse reaction. You should,
however, note that some reddening of the skin can
appear under the belt during and for a short time after a
session.
Note
• An effective treatment should not cause undue
discomfort.
Important
• Keep your unit out of the reach of children.
• The studs and pads must not be connected to other
objects.
• Do not use your unit at the same time as any other
device which transfers an electrical current into the body
(e.g. another muscle stimulator).
• Do not touch the pads or metal studs while the unit is
switched on.
• Do not use while driving or operating machinery.
• Your
abdominal unit should not be used with
SLENDERTONE
a garment from any other
SLENDERTONE
may result in an unbalanced stimulation and an
inefficient toning session.
•
will not accept responsibility if the
SLENDERTONE
guidelines and instructions supplied with this unit are
not followed.
units
NB: If you are in any doubt about using a slendertone
belt for any reason, please consult your doctor before
use.
Technical Specifications
Caring for your unit
Your unit should not be allowed to get wet or be left in excessive
sunlight. It may be cleaned regularly using a soft cloth, lightly
dampened in soapy water. Do not allow the interior of your unit to
become wet. Do not use detergents, alcohol, spray aerosols or
strong solvents on your unit.
Access to the interior of the unit is not required for maintenance
purposes.
If your unit is damaged, you should not use it but should return it
to
or your local distributor for replacement or repair.
SLENDERTONE
Repairs, service and modifications may not be carried out by
anyone other than qualified service personnel authorised by
.
SLENDERTONE
Note: Using leak-proof batteries is advised. You should never
leave the batteries inside your unit if you do not intend to use it
for a long period of time. If you do, the batteries may leak and
damage your unit. You should be aware that some batteries sold
as 'leak-proof' can still release some corrosive substances, which
may damage your unit. Under no circumstance should anything
other than the correct type of batteries 1.5v (lr03/ AAA) be used
with your unit. You should only insert the batteries in the manner
specified in this manual.
Disposing of the pads and batteries
Used pads and batteries must never be disposed of in a fire but in
accordance with your country's national laws governing the
disposal of such items.
When the
symbol appears the stimulus is significantly
reduced.
The signal gradually increases to a peak intensity level at the start
of a contraction phase (i.e. ramp up) and gradually decreases to
nothing at start of a relaxation phase (i.e. ramp down).
Accessories
When ordering new pads, you should only use those carrying the
brand. Any others may not be compatible with your
SLENDERTONE
unit and could degrade the minimum safety levels.
•
Adhesive Pads, containing:
SLENDERTONE
1 large adhesive pad
2 small adhesive pads Type 710 or 707
•
Belt
SLENDERTONE
•
Belt Extension
SLENDERTONE
Intended use: Muscle stimulator
Waveform: Symmetrical bi-phasic square waveform
product. Doing so
when measured into a resistive load.
Environmental Specifications
Operating: Temperature Range: 0 to 35˚C
Humidity: 20 to 65 % RH
Storage:
Temperature Range: 0 to 55˚C
Humidity: 10 to 90 % RH
Description of your unit's symbols:
There are a number of technical markings on your unit. These can
be explained as follows:
Inside the battery compartment '+' indicates positive polarity and '-
' indicates negative polarity. The batteries' position is also shown
by 3 embossed outlines in the base of the compartment.
The unit and belt are manufactured for Bio-Medical Research Ltd.,
Parkmore Business Park West, Galway, Ireland.
The unit re q u i res three 1.5 volt ( L R03) DC batteries. DC is indicated
by the symbol:
The Output Frequency indicates the number of pulses per second
transmitted by the unit. This is measured in hertz ( 'Hz').
Output (RMSA) mean the max. output root mean square current
for each channel.
Output (RMSV) mean the max. output root mean square voltage
for each channel.
This symbol means 'Attention, consult the accompanying
!
documents'.
This symbol means type BF equipment.
This symbol on your
conformity to the requirements of the Medical Device
Directive (93/42/EEC). 0366 is the number of the
0366
notified body (VDE).
SN stands for 'serial number'.
Inside the box, on the back of the unit is the serial number
specific to this unit. The letter preceding the number indicates the
year of manufacture, where 'A' denotes 1995, 'J' denotes 2004, 'K'
denotes 2005 etc.
The belt's batch number is represented on the belt packaging, by
the number corresponding with the LOT symbol.
Note: In accordance with the laws within the member states,
safety testing on the device should be carried out every two years.
Note: In compliance with German law, product safety testing must
be conducted every two years by an authorised test service.
Rated Outputs Voltage/Current:
Product Type: 514 (female
Parameter
Output RMSV
Output RMSA
Output Frequency
DC Component: Approx.
Positive Pulse Width:
Negative Pulse Width:
Interphase Interval:
Product Type: 517 (male
Parameter
Type 709 or 706
Output RMSV
Output RMSA
Output Frequency
DC Component: Approx.
Positive Pulse Width:
Negative Pulse Width:
Interphase Interval:
Material fabrics
Outer material: 100%Nylon, Binding: 82% Nylon, 18% Elastane
Hook & Loop: 100% Nylon, Foam: 100% Polyurethane
At the end of the product lifecycle, do not throw this
product into the normal household garbage, but bring
it to a collection point for the recycling of electronic
equipment.
Some product materials can be re-used if you bring
them to a recycling point. By re-using some parts or raw
materials from used products you make an important
contribution to the protection of the environment.
Please contact your local authorities if you need more
information about collection points in your area.
Waste Electrical and Electronic Equipment can have
potentially harmful effects on the enviro n m e n t . Incorrect
disposal can cause harmful toxins to build up in the air,
water and soil and can be harmful to human health
unit is to indicate
SLENDERTONE
)
FLEX MAX
500
1K
1K5
6.8V
10.7V
12.3V
14mA
11mA
8mA
50-95Hz.
50-95Hz.
50-95Hz.
0 C
0 C
0 C
200-350 µs 200-350 µs 200-350 µs
200-350 µs 200-350 µs 200-350 µs
100 µs
100 µs
100 µs
)
FLEX MAX
500
1K
1K5
7.1V
10.7V
12.2V
14mA
11mA
8mA
55-99Hz.
55-99Hz.
55-99Hz.
0 C
0 C
0 C
200–350 µs 200–350 µs 200–350 µs
200–350 µs 200–350 µs 200–350 µs
100 µs
100 µs
100 µs
.
11