Scan Params; Msr Input; Enabled - Motorola ET1 Integrator Manual

Enterprise tablet
Hide thumbs Also See for ET1:
Table of Contents

Advertisement

LCD Mode - Enables or disables LCD mode. LCD mode enhances the ability of the imager to read bar
codes from LCD displays such as cellphones (Scan Module Only).
Disable - Disables the LCD mode
Enable - Enables LCD mode.
When using the LCD mode, a degradation in performance may be observed and the aiming crosshair may
NOTE
blink until the bar code is decoded.
Illumination mode - Turns camera illumination on and off. This option is only available when camera is
selected in the Barcode input Scanner selection option.
On - Illumination is on.
Off - Illumination is off (default).
Inverse 1D Mode - This parameter allows the user to select decoding on inverse 1D bar codes.
Disable - Disables decoding of inverse 1D bar codes.
Enable - Enables decoding of only inverse 1D bar codes.
Auto - Allows decoding of both positive and inverse 1D bar codes.
Viewfinder Mode - Configures the Viewfinder modes supported for camera scanning.
Viewfinder Enabled - Enables only the viewfinder.
Static Reticle - Enables the viewfinder and a red reticle in the center of the screen which helps
selecting the bar code (default).

Scan Params

Allows the configuration of Code Id and decode feedback options.
Code ID Type - A Code ID character identifies the code type of a scanned bar code. This is useful when
the reader is decoding more than one code type. Select a code ID character to insert between the prefix
and the decoded symbol.
Code ID Type None - No prefix (default).
Code ID Type Aim - A standards based three character prefix.
Code ID Type Symbol - A Symbol defined single character prefix.
NOTE
Not all ringtones are fully supported as decode tones and those of longer length may be truncated when
used as a decode tone. The recommendation is to test the selected tone for operation before deployment
to a customer site.
Decode Audio Feedback - Select an audio tone to sound upon a good decode.
Decode Haptic Feedback - Enable the ET1 to vibrate upon a good decode (default - enabled).

MSR Input

Use MSR Input options to configure the MSR Input Plug-in for the profile.

Enabled

Enables or disables this plug-in. A check in the checkbox indicates that the plug-in is enabled.
DataWedge Configuration 4 - 17

Hide quick links: