4 - 12 ET1 Enterprise Tablet Integrator Guide
•
Interleaved 2of5
•
Length1 - Use to set decode lengths (default - 14). See
information.
•
Length2 - Use to set decode lengths (default - 10). See
information.
•
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the
checkbox indicates that redundancy is enabled (default - enabled).
•
Check Digit
•
No Check Digit - A check digit is not used. (default)
•
USS Check Digit - Select to check the integrity of all Interleaved 2 of 5 symbols to verify the data
complies with either the Uniform Symbology Specification (USS) check digit algorithm.
•
OPCC Check Digit - Select to check the integrity of all Interleaved 2 of 5 symbols to verify the data
complies with either the Optical Product Code Council (OPCC) check digit algorithm.
•
Report Check Digit - Transmit Interleaved 2 of 5 data with or without the check digit. A check in the
checkbox indicates to send I2of5 data with check digit (default - disabled).
•
Convert ITF-14 To EAN13 - Convert 14-character Interleaved 2 of 5 bar codes to EAN-13, and
transmit as EAN-13. The Interleaved 2 of 5 bar code must be enabled and must have a leading zero
and a valid EAN-13 check digit. A check in the checkbox indicates that the option is enabled (default -
disabled).
•
Composite AB
•
UCC Link Mode
•
Link Flag ignored - 1D component is transmitted regardless of whether a 2D component is
detected.
•
Always Linked - 1D and the 2D components are transmitted. If 2D is not present, the 1D
component is not transmitted.
•
Auto Discriminate - the digital scanner determines if there is a 2D portion, then transmits the 1D
component, as well as the 2D portion if present. (default).
•
UK Postal
•
Report Check Digit - Transmit UK Postal data with or without the check digit. A check in the
checkbox indicates to send UK Postal data with check digit (default - disabled).
•
Codabar
•
Length1 - Use to set decode lengths (default - 6). See
information.
•
Length2 - Use to set decode lengths (default - 55). See
information.
•
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the
checkbox indicates that redundancy is enabled (default - enabled).
•
CLSI Editing - Enable this parameter to strip the start and stop characters and insert a space after the
first, fifth, and tenth characters of a 14-character Codabar symbol. Enable this feature if the host
system requires this data format (default - disabled).
•
NOTIS Editing - Enable this parameter to strip the start and stop characters from a decoded Codabar
symbol. Enable this feature if the host system requires this data format (default - disabled).
Decode Lengths on page 4-14
Decode Lengths on page 4-14
Decode Lengths on page 4-14
Decode Lengths on page 4-14
for more
for more
for more
for more