Summary of Contents for Telguard TG-1 Express CDMA
Page 1
TG-1 Express CDMA Quick Install Guide COMPANY CONFIDENTIAL ® For use by TELGUARD customers only. June 5, 2014 Distribution to other parties strictly prohibited.
Foreword The Telguard model TG-1 Express CDMA cellular alarm communicator is UL Listed for Household Fire systems and Household Burglary systems. This means that the TG-1 Express CDMA may be used in Household Burglary systems, Household Fire systems or combined Household Burglary & Fire system as the primary communication path.
This excludes damage due to lightning, unauthorized modifications or installer error. Telular is not responsible for incidental or consequential damages. If a Telguard unit needs to be returned for repair, please return the product to the distributor that the unit was originally purchased from. The distributor will contact Telular to obtain an RMA based on the unit’s warranty eligibility.
Installation manual available at www.TelguardOnline.com. Panel-Supplied Power The Telguard TG-1 Express CDMA can usually be powered from the panel to which it is connected. It averages 45mA consumption while idle at 12V. Simply supply the Auxiliary power output from any voltage compatible (6.2V to 17V) panel.
Upon configuration, it can generate a relay trip output that can be connected to a zone input of the host alarm panel or used to activate remote annunciation devices. No Service Condition (NSC): Declared when the Telguard is unable to register ...
Step 2: Locate Unit and Measure Signal Strength (RSSI) Pick a spot next to the alarm panel where you think the Telguard will be mounted and place the unit down temporarily in that spot. With the alarm panel powered off,...
Once the unit activates it will begin operating in normal mode; LED #1 will be on solid. The first alarm is used only to activate the Telguard unit. The first alarm will NOT be transmitted to the central station. Trip several alarms on the alarm panel and verify that the central station received them by calling the central station operator.
In addition to the interface to the alarm panel, a single trip input may be connected to the terminal block of the TG-1 Express CDMA. When the input is tripped, a supervisory message is sent to the central station via the Telguard Communications Center.
Page 9
Opening and Closing reports must be enabled to report at all times. Telguard Interactive will repurpose the STC and Trip Input connections. Although it is highly recommended to use SLIC for most of the required wiring, Telguard Interactive can be wired in one of two ways:...
Telguard Interactive Wiring (using terminal block) Note: UL has not evaluated the Telguard Interactive feature. This feature cannot be used in UL Listed Installations. Specifications UL Listings UL Household Burglary (UL 1023) UL Household Fire (UL 985) Power Consumption ...
When flashing with LED #1, unit has failed Flashing activation. LED #4 TG-1 Express CDMA initialized Acknowledgement TG-1 Express CDMA is waiting for response from Telular Communications Center Idle, provisioned by CDMA network Fast Flash CDMA network provisioning in progress (½ sec)
Output Message Check input voltage STC LED flashes Optional None of power supplied 1 time. from the panel. The Telguard will continue to validate STC LED flashes Optional None signal strength, and 4 times. remove NSC when signal returns. Telguard...
Need help?
Do you have a question about the TG-1 Express CDMA and is the answer not in the manual?
Questions and answers