TROUBLESHOOTING
If the engine does not start
1. Check the fuel tank for sufficient fuel. Refill with fresh gasoline if necessary.
2. Check the engine oil. Fill to the upper limit with fresh oil.
3. Ensure that the fuel cock is open. The fuel cock is open when the lever is perpendicular to the
ground (straight up and down).
4. Check that the spark plug cap is securely attached to the spark plug.
5. Inspect the air filter. Clean or replace it if necessary.
6. Disconnect all electrical loads from the generator, and turn the engine switch on.
7. Follow the starting procedures in this manual on page 16.
If the engine still does not start
1. Pull the starter handle 5-6 times.
2. Remove and inspect the spark plug.
If the spark plug is dry
1. Ensure that there is fresh fuel in the tank and that the fuel cock is open.
2. Reinstall the spark plug and spark plug cap.
3. Try to start the engine again by following the starting procedures in this manual on page 16.
4. If the engine fails to start, take the generator to an authorized HITACHI service center.
If the spark plug is wet
1. Clean, gap, or replace the spark plug.
2. Reinstall the spark plug and spark plug cap.
3. Try to start the engine again by following the starting procedures in this manual on page 16.
4. If the engine fails to start, take the generator to an authorized HITACHI service center.
If there is no power to the receptacles
1. Turn the AC no fuse breaker "OFF" and disconnect all electrical loads from the generator.
2. Reconnect the electrical loads. Be sure that the plugs are securely connected to the receptacles and
turn the AC no fuse breaker "ON".
3. If there is still no power at the receptacles, take the generator to an authorized HITACHI service
center.

MAINTENANCE

IMPORTANCE OF MAINTENANCE
Good maintenance is essential for safe, economical, and trouble-free operation. It will also help
reduce air pollution.
WARNING:
Improper maintenance or failure to correct a problem before operation can cause
malfunction, serious injury, or death. Always follow the inspection and
maintenance recommendation and schedules in this user's manual.
The following pages include a maintenance schedule, routine inspection
procedures, and simple maintenance procedures using basic hand tools, to help
you properly care for your generator. If you are not comfortable with any
maintenance procedure, have the generator serviced by a professional technician.
Maintenance, replacement, or repair of the emission control devices and system
may be performed by any engine repair establishment or individual, using parts
that are "certified" to EU standards.
MAINTENANCE SAFETY
WARNING:
Always follow the procedures and precautions in the owner's manual. Failure to
properly follow maintenance instructions and precautions can lead to serious
injury or death.