4. Turn the starter switch to the "
If the engine won't start, turn the switch back to "I" (ON)
position and then wait for approximately 10 seconds to try it
again.
NOTE:
You might have to keep the starter running for at least 3
to 5 seconds, since the engine incorporates the
mechanism in it where the ignition circuit is activated
by the increase of hydraulic pressure.
In the following occasion, two or three trials may be
required for starting the engine:
(1) The very first starting of a new generator.
(2) After the refueling of the engine which has been
stopped due to fuel shortage.
(3) Starting after the oil filter change.
Even if the engine has already been warmed, be sure to
pull the choke knob.
5. Return the starter switch to "I" (ON) position soon after the
engine has started and then push the choke knob. In cold
weather, be sure to push it gradually.
6. Warm the engine up for a minute or two. Longer time would
be needed in cold weather.
NOTE:
If the oil level in the engine is low, the engine will not start. If the engine does not start,
check the oil level and add oil as needed.
To ensure maximum oil lubrication, place the generator on a level surface.
" (START) position.
English
Fig. 18
Open
Fig. 19
17